EUVIMEDEUVIMED entdecken
Crossref

Quadratic diffusion model with improved Mamba for low-dose CT blind super resolution

Xiebo Qiu, Xiaoqiang Zhao, Zhenrui Peng, Zhaoyang Song

Measurement Science and Technology · 31.07.2026 · 37 (30) · 305703

DOI: 10.1088/1361-6501/ae8d4c ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 31.07.2026. Verfasst von Xiebo Qiu und 3 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Industrial Support Project of Education Department of Gansu Province, Natural Science Foundation of Gansu Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Low-dose computed tomography (LDCT) images are obtained by reducing the x-ray radiation dose, which can reduce the risk of radiation exposure to patients. However, LDCT images are usually blurry due to the decreased number of photons reaching the detectors, which makes it difficult to discern meaningful anatomies for clinical diagnosis. Super-resolution (SR) methods have been proposed to improve the quality of LDCT images without increasing the radiation dose. In this paper, we propose a novel LDCT blind SR method, named the quadratic diffusion model with improved Mamba (DMIM). Specifically, we design a kernel-guided degradation predictor, which takes advantage of a generative diffusion-based framework to predict the blur kernel in a low-resolution (LR) LDCT image. Meanwhile, to reconstruct more accurate LDCT images with detailed information, both the predicted blur kernel and the LR LDCT images as prior knowledge are input into our designed multi-perception feature reconstructor (MPF reconstructor). Moreover, we design an improved vision state space denoising module (IV-Mamba) to help the MPF reconstructor to better remove the noise in valuable diagnostic information. Extensive experiments on three public CT datasets with two scale factors demonstrate that the proposed DMIM achieves superior quantitative and qualitative performance. Compared with the best-performing competing result under each setting, DMIM yields average improvements of 0.43 dB in peak signal-to-noise ratio, 0.025 in SSIM, and 0.029 in modulation transfer function.

Förderung

  • National Natural Science Foundation of China
  • Industrial Support Project of Education Department of Gansu Province
  • Natural Science Foundation of Gansu Province

Zitieren

APA

Qiu, X., Zhao, X., Peng, Z., & Song, Z. (2026). Quadratic diffusion model with improved Mamba for low-dose CT blind super resolution. Measurement Science and Technology, 37(30), 305703. https://doi.org/10.1088/1361-6501/ae8d4c

Vancouver

Qiu X, Zhao X, Peng Z, Song Z. Quadratic diffusion model with improved Mamba for low-dose CT blind super resolution. Measurement Science and Technology. 2026;37(30):305703. doi:10.1088/1361-6501/ae8d4c

BibTeX
@article{Qiu2026,
  author = {Qiu, Xiebo and Zhao, Xiaoqiang and Peng, Zhenrui and Song, Zhaoyang},
  title = {Quadratic diffusion model with improved Mamba for low-dose CT blind super resolution},
  journal = {Measurement Science and Technology},
  year = {2026},
  volume = {37},
  number = {30},
  pages = {305703},
  doi = {10.1088/1361-6501/ae8d4c}
}
Kostenlos starten →