Effects of gradient porosity and particle diameter on transpiration cooling for double-layer plates

Feilong Yao, Shiqiang Qin, Yang Li, Chun Shao, Zefei Zhu

International Journal of Modern Physics C · 16.05.2026

DOI: 10.1142/s0129183127500872 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Modern Physics C, online erschienen am 16.05.2026. Verfasst von Feilong Yao und 4 weiteren Autor:innen. Die Arbeit nennt 42 Literaturangaben. Gefördert von: Zhejiang Provincial Natural Science Foundation of China, the Fundamental Research Funds for the Provincial Universities of Zhejiang, the Key R&D Programs of Zhejiang Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Porous medium (PM) structure with a gradient porosity or a combination of different porosities is an effective method to improve the cooling performance of transpiration cooling. Novel structures with gradient porosity distributions are proposed to evaluate transpiration cooling performance on thermally challenged surfaces subjected to high-speed hot gas flow. The effects of inlet mass flow rate, gradient porosity and particle diameter on the injection pressure [Formula: see text] and cooling efficiency are investigated through numerical simulations. Although increasing the flow rate can improve the cooling efficiency of the upper wall, the corresponding coolant injection pressure significantly increases. As the particle diameter of the inner or outer porous plate decreases, the cooling performance of double-layer porous plates is better than that of a conventional single-layer porous plate, but the required injection pressure increases due to decreasing permeability. When the porosity of the outer porous plate remains unchanged, the average temperature of the upper wall remains almost unchanged with the increasing porosity of the inner plate, the deviation is negligible. In contrast, when the porosity of the inner porous plate remains unchanged, the cooling performance is enhanced with the decreasing porosity of the outer plate and [Formula: see text] is increased by about seven times. In addition, present results reveal that the cooling efficiency and temperature uniformity are significantly enhanced when the porosity decreases linearly along the positive x direction, and the required injection pressure [Formula: see text] is reduced by 38.6% compared with a uniform porous structure. The results obtained in this paper may provide important insights and promising solutions to prevent the heat transfer deterioration in PM structures.

Förderung

  • Zhejiang Provincial Natural Science Foundation of China
  • the Fundamental Research Funds for the Provincial Universities of Zhejiang
  • the Key R&D Programs of Zhejiang Province
  • the National Natural Science Foundation of China

Zitieren

APA

Yao, F., Qin, S., Li, Y., Shao, C., & Zhu, Z. (2026). Effects of gradient porosity and particle diameter on transpiration cooling for double-layer plates. International Journal of Modern Physics C. https://doi.org/10.1142/s0129183127500872

Vancouver

Yao F, Qin S, Li Y, Shao C, Zhu Z. Effects of gradient porosity and particle diameter on transpiration cooling for double-layer plates. International Journal of Modern Physics C. 2026. doi:10.1142/s0129183127500872

BibTeX
@article{Yao2026,
  author = {Yao, Feilong and Qin, Shiqiang and Li, Yang and Shao, Chun and Zhu, Zefei},
  title = {Effects of gradient porosity and particle diameter on transpiration cooling for double-layer plates},
  journal = {International Journal of Modern Physics C},
  year = {2026},
  doi = {10.1142/s0129183127500872}
}
Kostenlos starten →