Effect of Porosity and Injection Ratio on the Performance of Transpiration Cooling through Gyroids
International Journal of Turbomachinery, Propulsion and Power · 01.12.2023 · 8 (4) · 50
DOI: 10.3390/ijtpp8040050 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Turbomachinery, Propulsion and Power, online erschienen am 01.12.2023. Verfasst von Benjamin J. Brimacombe und 4 weiteren Autor:innen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council.
Abstract (Originalsprache)
This paper presents experimental measurements of adiabatic effectiveness for three transpiration cooling porosities (ϕ= 0.3, 0.4, and 0.5) constructed from gyroid lattice structures. To the authors’ knowledge, this is the first use of a Triply Periodic Minimal Surface (TPMS) function to produce transpiration test coupons of varying porosity. Polymer gyroid lattice structures were successfully printed using Stereolithography (SLA) down to ϕ= 0.3 for a print resolution of 25 microns and unit cell size of 2 mm. Cooling performance was measured in a small-scale wind tunnel. High-resolution Infrared Thermography was used to determine wall temperatures downstream of the porous section. When tested at both common blowing ratios (M = 0.029, 0.048, and 0.062) and common injection ratios (F = 0.010, 0.017, and 0.022) the cooling performance was found to be dependent on porosity for constant M but not for constant F. Having determined F as the more important parameter for comparison, results are presented alongside transpiration and effusion data from literature.
Förderung
- Engineering and Physical Sciences Research Council
Zitieren
APA
Brimacombe, B. J., Scobie, J. A., Flynn, J. M., Sangan, C. M., & Pountney, O. J. (2023). Effect of Porosity and Injection Ratio on the Performance of Transpiration Cooling through Gyroids. International Journal of Turbomachinery, Propulsion and Power, 8(4), 50. https://doi.org/10.3390/ijtpp8040050
Vancouver
Brimacombe BJ, Scobie JA, Flynn JM, Sangan CM, Pountney OJ. Effect of Porosity and Injection Ratio on the Performance of Transpiration Cooling through Gyroids. International Journal of Turbomachinery, Propulsion and Power. 2023;8(4):50. doi:10.3390/ijtpp8040050
BibTeX
@article{Brimacombe2023,
author = {Brimacombe, Benjamin J. and Scobie, James A. and Flynn, Joseph M. and Sangan, Carl M. and Pountney, Oliver J.},
title = {Effect of Porosity and Injection Ratio on the Performance of Transpiration Cooling through Gyroids},
journal = {International Journal of Turbomachinery, Propulsion and Power},
year = {2023},
volume = {8},
number = {4},
pages = {50},
doi = {10.3390/ijtpp8040050}
}