Protocol for Improving Care by FAster risk-STratification through use of high sensitivity point-of-care troponin in patients presenting with possible acute coronary syndrome in the EmeRgency department (ICare-FASTER): a stepped-wedge cluster randomised quality improvement initiative
BMJ Open · 2024
DOI: 10.1136/bmjopen-2023-083752 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift BMJ Open, 2024. Verfasst von John W Pickering und 18 weiteren Autor:innen. Beteiligte Einrichtung: Medicine, University of Otago Christchurch, Christchurch, New Zealand. Hauptthemen laut MEDLINE: Acute Coronary Syndrome, Emergency Service, Hospital, Quality Improvement. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: British Heart Foundation, Health Research Council of New Zealand, Siemens Healthineers.
Abstract (Originalsprache)
Introduction Clinical assessment in emergency departments (EDs) for possible acute myocardial infarction (AMI) requires at least one cardiac troponin (cTn) blood test. The turn-around time from blood draw to posting results in the clinical portal for central laboratory analysers is ~1–2 hours. New generation, high-sensitivity, point-of-care cardiac troponin I (POC-cTnI) assays use whole blood on a bedside (or near bedside) analyser that provides a rapid (8 min) result. This may expedite clinical decision-making and reduce length of stay. Our purpose is to determine if utilisation of a POC-cTnI testing reduces ED length of stay. We also aim to establish an optimised implementation process for the amended clinical pathway. Methods and analysis This quality improvement initiative has a pragmatic multihospital stepped-wedge cross-sectional cluster randomised design. Consecutive patients presenting to the ED with symptoms suggestive of possible AMI and having a cTn test will be included. Clusters (comprising one or two hospitals each) will change from their usual-care pathway to an amended pathway using POC-cTnI—the ‘intervention’. The dates of change will be randomised. Changes occur at 1 month intervals, with a minimum 2 month ‘run-in’ period. The intervention pathway will use a POC-cTnI measurement as an alternate to the laboratory-based cTn measurement. Clinical decision-making steps and logic will otherwise remain unchanged. The POC-cTnI is the Siemens (Erlangen Germany) Atellica VTLi high-sensitivity cTnI assay. The primary outcome is ED length of stay. The safety outcome is cardiac death or AMI within 30 days for patients discharged directly from the ED. Ethics and dissemination Ethics approval has been granted by the New Zealand Southern Health and Disability Ethics Committee, reference 21/STH/9. Results will be published in a peer-reviewed journal. Lay and academic presentations will be made. Māori-specific results will be disseminated to Māori stakeholders. Trial registration number ACTRN12619001189112.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Medicine, University of Otago Christchurch, Christchurch, New Zealand.
- Emergency, Christchurch Hospital, Christchurch, New Zealand.
- Waikato District Health Board, Hamilton, New Zealand.
- Heart Foundation of New Zealand, Auckland, New Zealand.
- Division of Cardiovascular Sciences, University of Manchester, The Victoria University of Manchester Campus, Manchester, UK.
- Cardiology, Christchurch Hospital, Christchurch, New Zealand.
ORCID-Profile: John W Pickering, Sarah J Lord, Laura Joyce, Arthur M Richards, Martin Than
Förderung
- British Heart Foundation
- Health Research Council of New Zealand
- Siemens Healthineers
Zitieren
APA
Pickering, J. W., Devlin, G., Body, R., Aldous, S., Jaffe, A. S., Apple, F. S., Mills, N., Troughton, R. W., Kavsak, P., Peacock, W. F., Cullen, L., Lord, S. J., Müller, C., Joyce, L., Frampton, C., Lacey, C. J., Richards, A. M., Pitama, S., & Than, M. (2024). Protocol for Improving Care by FAster risk-STratification through use of high sensitivity point-of-care troponin in patients presenting with possible acute coronary syndrome in the EmeRgency department (ICare-FASTER): a stepped-wedge cluster randomised quality improvement initiative. BMJ Open. https://doi.org/10.1136/bmjopen-2023-083752
Vancouver
Pickering JW, Devlin G, Body R, Aldous S, Jaffe AS, Apple FS, et al. Protocol for Improving Care by FAster risk-STratification through use of high sensitivity point-of-care troponin in patients presenting with possible acute coronary syndrome in the EmeRgency department (ICare-FASTER): a stepped-wedge cluster randomised quality improvement initiative. BMJ Open. 2024. doi:10.1136/bmjopen-2023-083752
BibTeX
@article{Pickering2024,
author = {Pickering, John W and Devlin, Gerard and Body, Richard and Aldous, Sally and Jaffe, Allan S and Apple, Fred S and Mills, Nicholas and Troughton, Richard W and Kavsak, Peter and Peacock, W Frank and Cullen, Louise and Lord, Sarah J and Müller, Christian and Joyce, Laura and Frampton, Chris and Lacey, Cameron James and Richards, Arthur M and Pitama, Suzanne and Than, Martin},
title = {Protocol for Improving Care by FAster risk-STratification through use of high sensitivity point-of-care troponin in patients presenting with possible acute coronary syndrome in the EmeRgency department (ICare-FASTER): a stepped-wedge cluster randomised quality improvement initiative},
journal = {BMJ Open},
year = {2024},
doi = {10.1136/bmjopen-2023-083752}
}
EUVIMED