Effect of change of high‐sensitivity troponin I assay on emergency department diagnosis and disposition of patients with possible acute coronary syndrome
Emergency Medicine Australasia · 2025
DOI: 10.1111/1742-6723.70022 ↗Kurz gefasst
Fachartikel in der Zeitschrift Emergency Medicine Australasia, 2025. Verfasst von John W Pickering und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, University of Otago Christchurch, Christchurch, New Zealand. Hauptthemen laut MEDLINE: Acute Coronary Syndrome, Troponin I, Emergency Service, Hospital. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objective
Changing cardiac troponin (cTn) assays may affect a hospital's admission and myocardial infarction rates. The effect of changing from a contemporary to high‐sensitivity (hs) cTnI assay has been well described, but the real‐life impact on disposition and diagnosis of changing from one hs‐cTnI assay to another has not.
Methods
All patients who received a troponin measurement in the ED during 16 weeks were adjudicated to identify those the attending physician investigated for possible acute coronary syndrome (ACS) and for clinical outcomes. The Abbott ARCHITECT hs‐cTnI assay was in use for the first 8 weeks, followed by the Beckman Coulter hs‐cTnI assay for the second 8 weeks.
Results
Fewer patients were investigated with the Abbott assay (2213), than the Beckman assay (2683). A larger proportion were investigated for ACS in the Abbott (64.8%) than the Beckman (60.3%) arm. Among those investigated for ACS the rate of myocardial infarction decreased on changing from Abbott (12.8%) to Beckman (8.8%). Adjusted odds of a myocardial infarction were lower for the Beckman arm, Odds Ratio 0.69 (95% CI 0.55 to 0.88). A lower proportion of Abbott than Beckman had myocardial injury (at least one ED cTnI ≥ upper reference limit) 26.4% compared with 29.8%. The proportion admitted to hospital decreased from the Abbott arm (42.5%) to the Beckman arm (36.8%).
Conclusions
A change in cTnI assay resulted in a decreased rate of myocardial infarction and admission despite an increase in rate of myocardial injury among patients investigated for ACS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medicine, University of Otago Christchurch, Christchurch, New Zealand.
- Department of Emergency Medicine, Christchurch Hospital, Christchurch, New Zealand.
- University of Otago Christchurch, Christchurch, New Zealand.
- Christchurch Hospital, Christchurch, New Zealand.
- Cardiology Department, Christchurch Hospital, Christchurch, New Zealand.
- Department of Surgery and Critical Care, University of Otago Christchurch, Christchurch, New Zealand.
ORCID-Profile: John W Pickering, Jamin Kim, Laura R Joyce, Martin P Than
Zitieren
APA
Pickering, J. W., Kelland, S., Williams, O., Kim, J., Aldous, S., Joyce, L. R., & Than, M. P. (2025). Effect of change of high‐sensitivity troponin I assay on emergency department diagnosis and disposition of patients with possible acute coronary syndrome. Emergency Medicine Australasia. https://doi.org/10.1111/1742-6723.70022
Vancouver
Pickering JW, Kelland S, Williams O, Kim J, Aldous S, Joyce LR, et al. Effect of change of high‐sensitivity troponin I assay on emergency department diagnosis and disposition of patients with possible acute coronary syndrome. Emergency Medicine Australasia. 2025. doi:10.1111/1742-6723.70022
BibTeX
@article{Pickering2025,
author = {Pickering, John W and Kelland, Scott and Williams, Otis and Kim, Jamin and Aldous, Sally and Joyce, Laura R and Than, Martin P},
title = {Effect of change of high‐sensitivity troponin I assay on emergency department diagnosis and disposition of patients with possible acute coronary syndrome},
journal = {Emergency Medicine Australasia},
year = {2025},
doi = {10.1111/1742-6723.70022}
}
EUVIMED