Deep learning-based image quality assessment for optical coherence tomography macular scans: a multicentre study
British Journal of Ophthalmology · 2024
DOI: 10.1136/bjo-2023-323871 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift British Journal of Ophthalmology, 2024. Verfasst von Ziqi Tang und 31 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong SAR, China. Hauptthemen laut MEDLINE: Deep Learning, Imaging, Three-Dimensional, Macula Lutea, Tomography, Optical Coherence. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: Innovation and Technology Fund, Bright Focus Foundation, Research Grants Council of the Hong Kong Special Administrative Region, China.
Abstract (Originalsprache)
Aims
To develop and externally test deep learning (DL) models for assessing the image quality of three-dimensional (3D) macular scans from Cirrus and Spectralis optical coherence tomography devices.
Methods
We retrospectively collected two data sets including 2277 Cirrus 3D scans and 1557 Spectralis 3D scans, respectively, for training (70%), fine-tuning (10%) and internal validation (20%) from electronic medical and research records at The Chinese University of Hong Kong Eye Centre and the Hong Kong Eye Hospital. Scans with various eye diseases (eg, diabetic macular oedema, age-related macular degeneration, polypoidal choroidal vasculopathy and pathological myopia), and scans of normal eyes from adults and children were included. Two graders labelled each 3D scan as gradable or ungradable, according to standardised criteria. We used a 3D version of the residual network (ResNet)-18 for Cirrus 3D scans and a multiple-instance learning pipline with ResNet-18 for Spectralis 3D scans. Two deep learning (DL) models were further tested via three unseen Cirrus data sets from Singapore and five unseen Spectralis data sets from India, Australia and Hong Kong, respectively.
Results
In the internal validation, the models achieved the area under curves (AUCs) of 0.930 (0.885–0.976) and 0.906 (0.863–0.948) for assessing the Cirrus 3D scans and Spectralis 3D scans, respectively. In the external testing, the models showed robust performance with AUCs ranging from 0.832 (0.730–0.934) to 0.930 (0.906–0.953) and 0.891 (0.836–0.945) to 0.962 (0.918–1.000), respectively.
Conclusions
Our models could be used for filtering out ungradable 3D scans and further incorporated with a disease-detection DL model, allowing a fully automated eye disease detection workflow.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong SAR, China.
- Zhejiang Lab, Hangzhou, Zhejiang, China.
- Department of Computer Science and Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China.
- Hong Kong Eye Hospital, Hong Kong SAR, China.
- Tsinghua Medicine, Tsinghua University, Beijing, China.
- School of Clinical Medicine, Beijing Tsinghua Changgung Hospital, Beijing, China.
ORCID-Profile: Ziqi Tang, Jason C Yam, Simon K H Szeto, Carmen K M Chan, Tien Yin Wong, Ching-Yu Cheng, Charumathi Sabanayagam, Yih Chung Tham, Giridhar Anantharaman, Rajiv Raman, Vincent L Yuen, Nelson Kei, Timothy Y Y Lai, Clement C Tham, Carol Y Cheung
Förderung
- Innovation and Technology Fund
- Bright Focus Foundation
- Research Grants Council of the Hong Kong Special Administrative Region, China
Zitieren
APA
Tang, Z., Wang, X., Ran, A. R., Yang, D., Ling, A., Yam, J. C., Zhang, X., Szeto, S. K. H., Chan, J., Wong, C. Y. K., Hui, V. W. K., Chan, C. K. M., Wong, T. Y., Cheng, C. Y., Sabanayagam, C., Tham, Y. C., Liew, G., Anantharaman, G., Raman, R., …, & Cheung, C. Y. (2024). Deep learning-based image quality assessment for optical coherence tomography macular scans: a multicentre study. British Journal of Ophthalmology. https://doi.org/10.1136/bjo-2023-323871
Vancouver
Tang Z, Wang X, Ran AR, Yang D, Ling A, Yam JC, et al. Deep learning-based image quality assessment for optical coherence tomography macular scans: a multicentre study. British Journal of Ophthalmology. 2024. doi:10.1136/bjo-2023-323871
BibTeX
@article{Tang2024,
author = {Tang, Ziqi and Wang, Xi and Ran, An Ran and Yang, Dawei and Ling, Anni and Yam, Jason C and Zhang, Xiujuan and Szeto, Simon K H and Chan, Jason and Wong, Cherie Y K and Hui, Vivian W K and Chan, Carmen K M and Wong, Tien Yin and Cheng, Ching-Yu and Sabanayagam, Charumathi and Tham, Yih Chung and Liew, Gerald and Anantharaman, Giridhar and Raman, Rajiv and Cai, Yu and Che, Haoxuan and Luo, Luyang and Liu, Quande and Wong, Yiu Lun and Ngai, Amanda K Y and Yuen, Vincent L and Kei, Nelson and Lai, Timothy Y Y and Chen, Hao and Tham, Clement C and Heng, Pheng-Ann and Cheung, Carol Y},
title = {Deep learning-based image quality assessment for optical coherence tomography macular scans: a multicentre study},
journal = {British Journal of Ophthalmology},
year = {2024},
doi = {10.1136/bjo-2023-323871}
}
EUVIMED