Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, 2024. Verfasst von Luka C Liebrand und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering & Physics, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Deep Learning, Magnetic Resonance Imaging, Imaging, Three-Dimensional, Nervous System Diseases. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Health~Holland.
Abstract (Originalsprache)
Objective
To compare compressed sensing (CS) and the Cascades of Independently Recurrent Inference Machines (CIRIM) with respect to image quality and reconstruction times when 12-fold accelerated scans of patients with neurological deficits are reconstructed. Materials and Methods Twelve-fold accelerated 3D T2-FLAIR images were obtained from a cohort of 62 patients with neurological deficits on 3 T MRI. Images were reconstructed offline via CS and the CIRIM. Image quality was assessed in a blinded and randomized manner by two experienced interventional neuroradiologists and one experienced pediatric neuroradiologist on imaging artifacts, perceived spatial resolution (sharpness), anatomic conspicuity, diagnostic confidence, and contrast. The methods were also compared in terms of self-referenced quality metrics, image resolution, patient groups and reconstruction time. In ten scans, the contrast ratio (CR) was determined between lesions and white matter. The effect of acceleration factor was assessed in a publicly available fully sampled dataset, since ground truth data are not available in prospectively accelerated clinical scans. Specifically, 451 FLAIR scans, including scans with white matter lesions, were adopted from the FastMRI database to evaluate structural similarity (SSIM) and the CR of lesions and white matter on ranging acceleration factors from four-fold up to 12-fold.
Results
Interventional neuroradiologists significantly preferred the CIRIM for imaging artifacts, anatomic conspicuity, and contrast. One rater significantly preferred the CIRIM in terms of sharpness and diagnostic confidence. The pediatric neuroradiologist preferred CS for imaging artifacts and sharpness. Compared to CS, the CIRIM reconstructions significantly improved in terms of imaging artifacts and anatomic conspicuity (p < 0.01) for higher resolution scans while yielding a 28% higher SNR (p = 0.001) and a 5.8% lower CR (p = 0.04). There were no differences between patient groups. Additionally, CIRIM was five times faster than CS was. An increasing acceleration factor did not lead to changes in CR (p = 0.92), but led to lower SSIM (p = 0.002).
Discussion
Patients with neurological deficits can undergo MRI at a range of moderate to high acceleration. DL reconstruction outperforms CS in terms of image resolution, efficient denoising with a modest reduction in contrast and reduced reconstruction times.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering & Physics, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands.
- Amsterdam Neuroscience, Brain Imaging, Amsterdam, The Netherlands.
- Department of Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands.
- Fondation Rothschild Hospital, 29 Rue Manin, Paris, France.
- Department of Biomedical Engineering & Physics, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands. m.w.a.caan@amsterdamumc.nl.
- Amsterdam Neuroscience, Brain Imaging, Amsterdam, The Netherlands. m.w.a.caan@amsterdamumc.nl.
Förderung
- Health~Holland
Zitieren
APA
Liebrand, L. C., Karkalousos, D., Poirion, É., Emmer, B. J., Roosendaal, S. D., Marquering, H. A., Majoie, C. B. L. M., Savatovsky, J., & Caan, M. W. A. (2024). Deep learning for efficient reconstruction of highly accelerated 3D FLAIR MRI in neurological deficits. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-024-01200-8
Vancouver
Liebrand LC, Karkalousos D, Poirion É, Emmer BJ, Roosendaal SD, Marquering HA, et al. Deep learning for efficient reconstruction of highly accelerated 3D FLAIR MRI in neurological deficits. Magnetic Resonance Materials in Physics, Biology and Medicine. 2024. doi:10.1007/s10334-024-01200-8
BibTeX
@article{Liebrand2024,
author = {Liebrand, Luka C and Karkalousos, Dimitrios and Poirion, Émilie and Emmer, Bart J and Roosendaal, Stefan D and Marquering, Henk A and Majoie, Charles B L M and Savatovsky, Julien and Caan, Matthan W A},
title = {Deep learning for efficient reconstruction of highly accelerated 3D FLAIR MRI in neurological deficits},
journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
year = {2024},
doi = {10.1007/s10334-024-01200-8}
}
EUVIMED