EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access · CC BY 4.0

Establishment and evaluation of a rapid method for the detection of bacterial pneumonia in hospitalized patients via multiplex PCR–capillary electrophoresis (MPCE)

Jie Wang iD, Pei Zhao iD, Mengchuan Zhao, Duoxiao Zhang, Shan Chen, Ying Liu, Yuan Gao, Yanqing Tie, Zhishan Feng iD

Microbiology Spectrum · 2024

DOI: 10.1128/spectrum.01202-24 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Microbiology Spectrum, 2024. Verfasst von Jie Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Diagnosis, Hebei Medical University, Shijiazhuang, Hebei, China. Hauptthemen laut MEDLINE: Electrophoresis, Capillary, Multiplex Polymerase Chain Reaction, Sensitivity and Specificity, Bacteria. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cost-effective molecular diagnostic techniques for bacterial pneumonia are limited. We designed primers for 13 bacteria, performed multiplex nucleic acid detection through fragment analysis to obtain pathogen identification results, and established a multiplex PCR–capillary electrophoresis (MPCE) method, which can simultaneously detect 13 pathogens associated with bacterial pneumonia. The sensitivity, specificity, and reproducibility of the MPCE assay were tested, and 420 clinical samples were used to assess the clinical detection ability of MPCE, with the culture method used as a reference. Samples with inconsistent results detected by the two methods were sent for Sanger sequencing. The minimum detection limit of MPCE for 13 bacteria was 6.0 × 10 3 cfu/mL~2.0 × 10 6 cfu/mL. No cross-reactivity was observed with other pathogens. The percentage of agreement for reproducibility analysis reached 100%. For the 420 sputum samples, when the culture method was used as the reference, the sensitivity of MPCE to 13 bacteria ranged from 80% to 100%. The specificity for 13 bacteria ranged from 67.1% to 100%. The percentage of agreement between the MPCE and the culture method ranged from 69.7% to 100%. There was no statistically significant difference ( P > 0.05) in the detection of Escherichia coli , Enterobacter cloacae complex , Staphylococcus aureus , methicillin-resistant S. aureus, Streptococcus pyogenes , Moraxella catarrhalis , or Legionella pneumophila between the MPCE and the culture method. Clinical samples with negative cultures but positive MPCE results were validated by Sanger sequencing, and the results were consistent with those of MPCE. The MPCE method has high sensitivity and specificity for bacterial pneumonia, enabling the simultaneous and rapid detection of multiple pathogens. It is cost-effective and has potential for clinical application. IMPORTANCE This study successfully established a multiplex PCR–capillary electrophoresis detection system that can simultaneously detect 13 pathogens through a single detection method, significantly improving clinical efficiency. It is cost-effective and has potential for clinical application.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electrophoresis, CapillaryMultiplex Polymerase Chain ReactionSensitivity and SpecificityBacteriaPneumonia, BacterialHumansReproducibility of ResultsFemaleSputumMaleLimit of DetectionMolecular Diagnostic TechniquesMiddle Aged

Stichwörter der Autor:innen

bacteriacapillary electrophoresismultiplex PCRpneumonia

Autor:innen und Institutionen

  • Department of Laboratory Diagnosis, Hebei Medical University, Shijiazhuang, Hebei, China.
  • Department of Clinical Laboratory, Hebei General Hospital, Shijiazhuang, Hebei, China.
  • Hebei Key Laboratory of Molecular Medicine, Hebei Clinical Research Center for Laboratory Medicine, Shijiazhuang, Hebei, China.
  • Department of Reagent Research and Development, Ningbo Health Gene Technologies Co., Ltd, Ningbo, Zhejiang, China.

ORCID-Profile: Jie Wang, Pei Zhao, Zhishan Feng

Zitieren

APA

Wang, J., Zhao, P., Zhao, M., Zhang, D., Chen, S., Liu, Y., Gao, Y., Tie, Y., & Feng, Z. (2024). Establishment and evaluation of a rapid method for the detection of bacterial pneumonia in hospitalized patients via multiplex PCR–capillary electrophoresis (MPCE). Microbiology Spectrum. https://doi.org/10.1128/spectrum.01202-24

Vancouver

Wang J, Zhao P, Zhao M, Zhang D, Chen S, Liu Y, et al. Establishment and evaluation of a rapid method for the detection of bacterial pneumonia in hospitalized patients via multiplex PCR–capillary electrophoresis (MPCE). Microbiology Spectrum. 2024. doi:10.1128/spectrum.01202-24

BibTeX
@article{Wang2024,
  author = {Wang, Jie and Zhao, Pei and Zhao, Mengchuan and Zhang, Duoxiao and Chen, Shan and Liu, Ying and Gao, Yuan and Tie, Yanqing and Feng, Zhishan},
  title = {Establishment and evaluation of a rapid method for the detection of bacterial pneumonia in hospitalized patients via multiplex PCR–capillary electrophoresis (MPCE)},
  journal = {Microbiology Spectrum},
  year = {2024},
  doi = {10.1128/spectrum.01202-24}
}
Kostenlos starten →