EUVIMEDEUVIMED entdecken
Validierungsstudie

Developmental Validation of the Microreader 23HS Plex ID System: A Novel Supplementary Non‐CODIS STR Multiplex Assay for Forensic Application

Hui Li iD, He Ren, Fan Yang, Man Chen, Weifen Sun, Lei Jiang, Zhixiao Gao, Yacheng Liu, Xiling Liu

ELECTROPHORESIS · 2024

DOI: 10.1002/elps.202400106 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift ELECTROPHORESIS, 2024. Verfasst von Hui Li und 8 weiteren Autor:innen. Beteiligte Einrichtung: Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Key Laboratory of Forensic Science, Ministry of Justice, Academy of…. Hauptthemen laut MEDLINE: Microsatellite Repeats, Forensic Genetics. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Science and Technology Commission of Shanghai Municipality, Ministry of Finance of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A novel supplementary non‐CODIS STR multiplex assay designated as the “Microreader 23HS Plex ID System” was developed. The Microreader 23HS Plex ID System enables simultaneous profiling of 23 STR loci and the amelogenin locus. The majority of these loci are non‐CODIS STRs (D4S2408, D9S2157, D20S161, D3S2459, D18S1364, D13S305, D1S2142, D19S400, D6S1017, D7S1517, D2S1776, D2S1360, D3S1744, D16S3391, D3S1545, D11S4463, D20S85, D1S549, D10S2325, D21S2055), with the exception of three CODIS STRs (D2S441, D12S391, and D22S1045). Followed the recommendations of Scientific Working Group on DNA Analysis Methods (SWGDAM) and the Chinese validation standards, a comprehensive set of validation studies were conducted, encompassing PCR conditions, stutter ratio and peak height balance, sensitivity, precision and accuracy, reproducibility, species specificity, inhibition, as well as mixture testing. The results demonstrated that the Microreader 23HS Plex ID System is a reliable and robust assay, with well‐balanced peak heights, high precision and accuracy, species specificity, and resistance to common inhibitors. The sensitivity of the assay was determined to be 0.125 ng of template DNA. In mixture study, all minor alleles were detected in two‐sample mixtures across various ratios (1:19, 1:9, 1:4, 3:7, 2:3, 1:1, 3:2, 4:1, 9:1, and 19:1). In population study, a total of 500 unrelated individuals of Han ethnicity from East China were genotyped. The allele frequencies and forensic population genetic parameters were calculated, with a cumulative random match probability of 7.757 × 10 −27 , and a total power of discrimination exceeding 0.999,999,999,999,999,999,999,999,99. In conclusion, the Microreader 23HS Plex ID System shows promise as a valuable supplementary tool for forensic applications, particularly in addressing complex kinship testing and challenges posed by STR mutation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Microsatellite RepeatsForensic GeneticsHumansReproducibility of ResultsMultiplex Polymerase Chain ReactionAnimalsDNA FingerprintingElectrophoresis, CapillarySpecies SpecificitySensitivity and Specificity

Stichwörter der Autor:innen

SWGDAMforensicnon‐CODIS short tandem repeatsvalidation

Autor:innen und Institutionen

  • Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Key Laboratory of Forensic Science, Ministry of Justice, Academy of Forensic Sciences, Shanghai, China.
  • Beijing Police College, Beijing, China.
  • Key Laboratory of Forensic Evidence and Science Technology, Ministry of Public Security, Institute of Forensic Science, Shanghai, China.
  • Suzhou Microread Genetics, Suzhou, China.
  • Beijing Tongda Shoucheng Institute of Forensic Science, Beijing, China.

ORCID-Profile: Hui Li

Förderung

  • National Key Research and Development Program of China
  • Science and Technology Commission of Shanghai Municipality
  • Ministry of Finance of China

Zitieren

APA

Li, H., Ren, H., Yang, F., Chen, M., Sun, W., Jiang, L., Gao, Z., Liu, Y., & Liu, X. (2024). Developmental Validation of the Microreader 23HS Plex ID System: A Novel Supplementary Non‐CODIS STR Multiplex Assay for Forensic Application. ELECTROPHORESIS. https://doi.org/10.1002/elps.202400106

Vancouver

Li H, Ren H, Yang F, Chen M, Sun W, Jiang L, et al. Developmental Validation of the Microreader 23HS Plex ID System: A Novel Supplementary Non‐CODIS STR Multiplex Assay for Forensic Application. ELECTROPHORESIS. 2024. doi:10.1002/elps.202400106

BibTeX
@article{Li2024,
  author = {Li, Hui and Ren, He and Yang, Fan and Chen, Man and Sun, Weifen and Jiang, Lei and Gao, Zhixiao and Liu, Yacheng and Liu, Xiling},
  title = {Developmental Validation of the Microreader 23HS Plex ID System: A Novel Supplementary Non‐CODIS STR Multiplex Assay for Forensic Application},
  journal = {ELECTROPHORESIS},
  year = {2024},
  doi = {10.1002/elps.202400106}
}
Kostenlos starten →