Performance evaluation of the high-throughput quantitative Alinity m BK virus assay
Journal of Clinical Microbiology · 2024
DOI: 10.1128/jcm.01354-23 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Microbiology, 2024. Verfasst von Julie W Hirschhorn und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology and Laboratory Medicine, Medical University of South Carolina, Charleston, South Carolina, USA. Hauptthemen laut MEDLINE: BK Virus, Kidney Transplantation, Polyomavirus Infections, Nucleic Acids. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BK virus (BKV) infection or reactivation in immunocompromised individuals can lead to adverse health consequences including BKV-associated nephropathy (BKVAN) in kidney transplant patients and BKV-associated hemorrhagic cystitis (BKV-HC) in allogeneic hematopoietic stem cell transplant recipients. Monitoring BKV viral load plays an important role in post-transplant patient care. This study evaluates the performance of the Alinity m BKV Investigational Use Only (IUO) assay. The linearity of the Alinity m BKV IUO assay had a correlation coefficient of 1.000 and precision of SD ≤ 0.25 Log IU/mL for all panel members tested (2.0–7.3 Log IU/mL). Detection rate at 50 IU/mL was 100%. Clinical plasma specimens tested comparing Alinity m BKV IUO to ELITech MGB Alert BKV lab-developed test (LDT) on the Abbott m 2000 platform using specimen extraction protocols for DNA or total nucleic acid (TNA) resulted in coefficient of correlation of 0.900 and 0.963, respectively, and mean bias of 0.03 and −0.54 Log IU/mL, respectively. Alinity m BKV IUO compared with Altona RealStar BKV and Roche cobas BKV assays demonstrated coefficient of correlation of 0.941 and 0.980, respectively, and mean bias of −0.47 and −0.31 Log IU/mL, respectively. Urine specimens tested on Alintiy m BKV IUO and ELITech BKV LDT using TNA specimen extraction had a coefficient of correlation of 0.917 and mean bias of 0.29 Log IU/mL. The Alinity m BKV IUO assay was performed with high precision across the dynamic range and correlated well with other available BKV assays. IMPORTANCE BK virus (BKV) in transplant patients can lead to adverse health consequences. Viral load monitoring is important in post-transplant patient care. This study evaluates the Alinity m BKV assay with currently available assays.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pathology and Laboratory Medicine, Medical University of South Carolina, Charleston, South Carolina, USA.
- Molecular Diagnostics of Abbott, Des Plaines, Illinois, USA.
- Department of Pathology, Montefiore Medical Center, Bronx, New York, USA.
- TriCore Reference Laboratories, Albuquerque, New Mexico, USA.
ORCID-Profile: Erika Orner, D Yitzchak Goldstein
Zitieren
APA
Hirschhorn, J. W., Sasaki, M. M., Kegl, A., Akter, T., Dickerson, T., Narlieva, M., Nhan, N., Liu, T., Jim, P., Young, S., Orner, E., Thwe, P., Lucic, D., & Goldstein, D. Y. (2024). Performance evaluation of the high-throughput quantitative Alinity m BK virus assay. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.01354-23
Vancouver
Hirschhorn JW, Sasaki MM, Kegl A, Akter T, Dickerson T, Narlieva M, et al. Performance evaluation of the high-throughput quantitative Alinity m BK virus assay. Journal of Clinical Microbiology. 2024. doi:10.1128/jcm.01354-23
BibTeX
@article{Hirschhorn2024,
author = {Hirschhorn, Julie W and Sasaki, Mark M and Kegl, April and Akter, Tanjina and Dickerson, Tanisha and Narlieva, Momka and Nhan, Nhi and Liu, Tianxi and Jim, Patricia and Young, Stephen and Orner, Erika and Thwe, Phyu and Lucic, Danijela and Goldstein, D Yitzchak},
title = {Performance evaluation of the high-throughput quantitative Alinity m BK virus assay},
journal = {Journal of Clinical Microbiology},
year = {2024},
doi = {10.1128/jcm.01354-23}
}
EUVIMED