Evaluationsstudie

Evaluation of a Standardized Laboratory-Developed Assay for Quantification of BK Virus in Renal Transplant Recipients

Nguyen Manh Dung, Nguyen Van Duc, Pham Quoc Toan, Chu Duc Minh, Nguyen Huu Ben, Nguyen Minh Phuong, Nguyen Tung Linh, Hoang Xuan Cuong, Dao Hong Nam, Patrice N Marche, Hoang Xuan Su

Transplantation Proceedings · 2026-07 · 58 (6) · 961-967

DOI: 10.1016/j.transproceed.2026.06.009 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Transplantation Proceedings, 2026-07. Verfasst von Nguyen Manh Dung und 10 weiteren Autor:innen. Beteiligte Einrichtung: Anesthesia and Critical Care Department, 108 Military Central Hospital, Hanoi, Vietnam. Electronic address: ndungsinh@gmail.com. Hauptthemen laut MEDLINE: BK Virus, Kidney Transplantation, Polyomavirus Infections, Tumor Virus Infections. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben. Gefördert von: Vietnam Military Medical University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: This study aims to evaluate the clinical performance of an in-house laboratory-developed assay (LDA) calibrated against the first World Health Organization (WHO) international standard for quantification of BK virus (BKV) in recipients of renal transplants. METHODS: A total of 83 samples were collected from patients who underwent renal transplantation at Military Hospital 103, Vietnam Military Medical University. BKV loads were measured using an in-house LDA in comparison with the Altona assay on urine and plasma samples. RESULTS: The limit of detection was established against the first WHO international standard and was estimated to be 135 IU/mL. The intra-assay and interassay coefficients of variation ranged from 0.42% to 1.13% and from 1.71% to 2.47%, respectively. The comparative evaluation of the LDA with the Altona assay on 83 clinical samples showed the diagnostic sensitivity and specificity of the LDA to be 98.04% and 90.62%, respectively. The Kappa value of 0.897 (95% CI, 0.781-0.975) showed a good agreement. For 50 quantitative results obtained by the two assays, excellent agreement and strong correlation were observed by linear regression (r2 = 0.95 for all samples), and Passing-Bablok regression analysis was used for method comparisons; the Bland-Altman plot analysis did not show any mean difference between measured values of the two assays for all samples. CONCLUSION: The LDA had good analytical and clinical performance for quantification of BKV as compared with the Altona assay. This LDA calibrated against the first WHO international standard could be useful for monitoring BKV replication in recipients of renal transplants in resource-challenged settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BK VirusKidney TransplantationPolyomavirus InfectionsTumor Virus InfectionsHumansReproducibility of ResultsViral Load

Autor:innen und Institutionen

  • Anesthesia and Critical Care Department, 108 Military Central Hospital, Hanoi, Vietnam. Electronic address: ndungsinh@gmail.com.
  • Department of Nephrology and Hemodialysis, Military Hospital 103, Vietnam Military Medical University, Hanoi, Vietnam.
  • Institute of Biomedicine and Pharmacy, Vietnam Military Medical University, Hanoi, Vietnam.
  • Department of Occupational Medicine, Vietnam Military Medical University, Hanoi, Vietnam.
  • Institute of Health Sciences, Ho Chi Minh City University of Technology, Ho Chi Minh City, Vietnam.
  • Vietnam Military Medical University at Ho Chi Minh City, Vietnam.

Förderung

  • Vietnam Military Medical University

Zitieren

APA

Dung, N. M., Van Duc, N., Toan, P. Q., Minh, C. D., Ben, N. H., Phuong, N. M., Linh, N. T., Cuong, H. X., Nam, D. H., Marche, P. N., & Su, H. X. (2026). Evaluation of a Standardized Laboratory-Developed Assay for Quantification of BK Virus in Renal Transplant Recipients. Transplantation Proceedings, 58(6), 961-967. https://doi.org/10.1016/j.transproceed.2026.06.009

Vancouver

Dung NM, Van Duc N, Toan PQ, Minh CD, Ben NH, Phuong NM, et al. Evaluation of a Standardized Laboratory-Developed Assay for Quantification of BK Virus in Renal Transplant Recipients. Transplantation Proceedings. 2026;58(6):961-967. doi:10.1016/j.transproceed.2026.06.009

BibTeX
@article{Dung2026,
  author = {Dung, Nguyen Manh and Van Duc, Nguyen and Toan, Pham Quoc and Minh, Chu Duc and Ben, Nguyen Huu and Phuong, Nguyen Minh and Linh, Nguyen Tung and Cuong, Hoang Xuan and Nam, Dao Hong and Marche, Patrice N and Su, Hoang Xuan},
  title = {Evaluation of a Standardized Laboratory-Developed Assay for Quantification of BK Virus in Renal Transplant Recipients},
  journal = {Transplantation Proceedings},
  year = {2026},
  volume = {58},
  number = {6},
  pages = {961--967},
  doi = {10.1016/j.transproceed.2026.06.009}
}
Kostenlos starten →