Evaluation of a point-of-care multiplex immunochromatographic assay for the diagnosis of typhoid: results from a retrospective diagnostic accuracy study

Rumina Hasan, Zahida Azizullah, Hina Shams, Sabine Dittrich, Jason R Andrews iD, Richelle C Charles, Javan Esfandiari, Dhammika Gunasekera, Kevin K A Tetteh, Jyotshna Sapkota iD

Journal of Clinical Microbiology · 2024

DOI: 10.1128/jcm.00428-24 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Clinical Microbiology, 2024. Verfasst von Rumina Hasan und 9 weiteren Autor:innen. Beteiligte Einrichtung: Aga Khan University, Karachi, Pakistan. Hauptthemen laut MEDLINE: Typhoid Fever, Sensitivity and Specificity, Point-of-Care Systems, Antibodies, Bacterial. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

There is a clear medical need for an accurate diagnostic test for typhoid that can be performed at point of care. Two antigens (lipopolysaccharide [LPS] and hemolysin E [HlyE]) have recently been identified that can distinguish typhoid from other bacterial infections. Here, we present the results of a diagnostic accuracy study of the Dual Path Platform (DPP) Typhoid assay (Chembio) that detects IgA to both LPS and HlyE using blood culture as the reference standard. This was a retrospective, observational, laboratory study conducted at the Aga Khan University research laboratory, Pakistan, to evaluate the sensitivity and specificity of the DPP Typhoid assay, using archived frozen serum samples collected during a previous typhoid diagnostic accuracy study (NCT04801602). The sensitivity, specificity, and accuracy (area under the receptor operating characteristics curve [AUC]) were then assessed using the manufacturer’s and Youden’s optimal thresholds. In total, 385 samples were included in the analysis. Using the manufacturer’s thresholds, the sensitivity, specificity, and AUC were 97.8% (95% confidence interval [CI] 94.6–99.2), 65.3% (95% CI 58.5–71.6), and 81.5% (95% CI 75.5–85.3), respectively. At Youden’s optimal threshold, the overall sensitivity of the DPP Typhoid assay was 89.7% and the specificity was 82.2%. In latent class modeling compared with other nine rapid diagnostic tests evaluated from the same cohort sample, the DPP Typhoid assay demonstrated the highest balanced accuracy (89.2%). The DPP Typhoid assay demonstrated a high diagnostic accuracy for typhoid fever. However, further adjustment to new thresholds is recommended to enhance its performance capabilities. IMPORTANCE Currently available diagnostic tests for typhoid have several limitations, including low sensitivity and specificity. Dual Path Platform Typhoid assay is a multiplex rapid test that detects IgA antibodies to lipopolysaccharide and hemolysin E antigen. It is considered to have high sensitivity and specificity, and its results were found to be highly correlated with ELISA results. However, very few studies have been conducted to evaluate this test and limited information about the accuracy of this test is present. Hence, this study evaluated the new typhoid test.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Typhoid FeverSensitivity and SpecificityPoint-of-Care SystemsAntibodies, BacterialHumansRetrospective StudiesFemaleMaleAdolescentAdultAntigens, BacterialChildSalmonella typhiImmunoglobulin APakistanYoung AdultChromatography, AffinityLipopolysaccharidesHemolysin ProteinsChild, PreschoolMiddle AgedImmunoassay

Stichwörter der Autor:innen

Salmonella Typhidiagnosticenteric feverpoint-of-caretyphoid

Substanzen

Antibodies, BacterialAntigens, BacterialImmunoglobulin ALipopolysaccharidesHemolysin Proteins

Autor:innen und Institutionen

  • Aga Khan University, Karachi, Pakistan.
  • Faculty of Infectious and Tropical Diseases, London School of Hygiene and Tropical Medicine, London, United Kingdom.
  • Deggendorf Institut of Technology, European Campus Rottal-Inn, Pfarrkirchen, Germany.
  • FIND, Geneva, Switzerland.
  • Division of Infectious Diseases and Geographic Medicine, Stanford University School of Medicine, Stanford, California, USA.
  • Division of Infectious Diseases, Massachusetts General Hospital, Boston, Massachusetts, USA.

ORCID-Profile: Jason R Andrews, Jyotshna Sapkota

Zitieren

APA

Hasan, R., Azizullah, Z., Shams, H., Dittrich, S., Andrews, J. R., Charles, R. C., Esfandiari, J., Gunasekera, D., Tetteh, K. K., & Sapkota, J. (2024). Evaluation of a point-of-care multiplex immunochromatographic assay for the diagnosis of typhoid: results from a retrospective diagnostic accuracy study. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.00428-24

Vancouver

Hasan R, Azizullah Z, Shams H, Dittrich S, Andrews JR, Charles RC, et al. Evaluation of a point-of-care multiplex immunochromatographic assay for the diagnosis of typhoid: results from a retrospective diagnostic accuracy study. Journal of Clinical Microbiology. 2024. doi:10.1128/jcm.00428-24

BibTeX
@article{Hasan2024,
  author = {Hasan, Rumina and Azizullah, Zahida and Shams, Hina and Dittrich, Sabine and Andrews, Jason R and Charles, Richelle C and Esfandiari, Javan and Gunasekera, Dhammika and Tetteh, Kevin K A and Sapkota, Jyotshna},
  title = {Evaluation of a point-of-care multiplex immunochromatographic assay for the diagnosis of typhoid: results from a retrospective diagnostic accuracy study},
  journal = {Journal of Clinical Microbiology},
  year = {2024},
  doi = {10.1128/jcm.00428-24}
}
Kostenlos starten →