EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

High False‐Positivity Rates of Widal Rapid Diagnostic Tests Compared to the Quantitative Tube Method for Salmonella typhi Detection in the Northern Region of Ghana

Eric Awe, Oliver Nangkuu Deberu iD, Fredrick Gyilbagr, Prince Sampson Haruna, Alfred Faadenige Doglikuu, Jemilatu Gnuntimia Abdul-Hamid, Abdul-Hayyu Yidana Yakubu, Blessing Hlormah, Maurice Zaazie

Tropical Medicine & International Health · 2026

DOI: 10.1111/tmi.70159 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Tropical Medicine & International Health, 2026. Verfasst von Eric Awe und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Laboratory, Mauplus Healthcare Services, Tamale, Ghana. Hauptthemen laut MEDLINE: Typhoid Fever, Salmonella typhi, Agglutination Tests. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Early diagnosis of typhoid is important for reducing mortality. In the absence of a blood culture, the quantitative tube Widal test is the standard serological test used for the diagnosis of Salmonella typhi , but rapid test kits are largely used in Northern Ghana. Variations in the performance of rapid test kits have been noted in other studies. We compared the diagnostic performance of two rapid test kits to the quantitative Widal method.

Methods

This was a cross‐sectional study conducted from April to May 2024 in the Northern Region of Ghana. Quantitative tube Widal and rapid diagnostic tests using two different rapid test kits were performed using plasma collected from suspected Salmonella typhi patients.

Results

Of the 154 participants, most were females, 84 (54.5%). The quantitative tube Widal method detected 14 (9.1%) and 5 (3.2%) positive results for Salmonella typhi O and H antibodies, respectively, whereas the rapid diagnostic test kit type‐1(IgM/IgG) detected 101 (65.6%)/47 (30.5%) positive results, and the type‐2(IgM/IgG) detected 117 (75.9%)/39 (25.3%) positive results. The diagnostic performance of RDT Type 1 (IgM/IgG) was: sensitivity (85.7%/80.0%), specificity (36.4%/71.1%), PPV (11.9%/8.5%), and NPV (96.2%/99.1%). On the other hand, the performance of RDT Type 2 (IgM/IgG) was: sensitivity (85.7%/40.0%), specificity (25.0%/75.2%), PPV (10.3%/5.1%) and NPV (94.6%/97.4%).

Conclusion

We found both rapid diagnostic test kit types to have a sensitivity of 85.7% with a specificity below 38% for IgM. Both test kit types also had low positive predictive values below 12% with negative predictive values above 94% for both IgM and IgG, and therefore detected more false positives than true positives.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Typhoid FeverSalmonella typhiAgglutination TestsHumansGhanaFemaleCross-Sectional StudiesRapid Diagnostic TestsFalse Positive ReactionsAntibodies, BacterialSensitivity and SpecificityMaleAdultImmunoglobulin GReagent Kits, DiagnosticAdolescentChildYoung AdultChild, PreschoolMiddle AgedImmunoglobulin M

Stichwörter der Autor:innen

SalmonellaWidal testserological diagnosistyphoid fever

Substanzen

Antibodies, BacterialImmunoglobulin GReagent Kits, DiagnosticImmunoglobulin M

Autor:innen und Institutionen

  • Department of Medical Laboratory, Mauplus Healthcare Services, Tamale, Ghana.
  • Department of Medical Laboratory, Seventh Day Adventist Hospital (SDA), Tamale, Ghana.
  • Department of Medical Laboratory, Tamale Teaching Hospital (TTH), Tamale, Ghana.
  • Department of Pharmacy, Mauplus Healthcare Services, Tamale, Ghana.

ORCID-Profile: Oliver Nangkuu Deberu

Zitieren

APA

Awe, E., Deberu, O. N., Gyilbagr, F., Haruna, P. S., Doglikuu, A. F., Abdul-Hamid, J. G., Yakubu, A. Y., Hlormah, B., & Zaazie, M. (2026). High False‐Positivity Rates of Widal Rapid Diagnostic Tests Compared to the Quantitative Tube Method for Salmonella typhi Detection in the Northern Region of Ghana. Tropical Medicine & International Health. https://doi.org/10.1111/tmi.70159

Vancouver

Awe E, Deberu ON, Gyilbagr F, Haruna PS, Doglikuu AF, Abdul-Hamid JG, et al. High False‐Positivity Rates of Widal Rapid Diagnostic Tests Compared to the Quantitative Tube Method for Salmonella typhi Detection in the Northern Region of Ghana. Tropical Medicine & International Health. 2026. doi:10.1111/tmi.70159

BibTeX
@article{Awe2026,
  author = {Awe, Eric and Deberu, Oliver Nangkuu and Gyilbagr, Fredrick and Haruna, Prince Sampson and Doglikuu, Alfred Faadenige and Abdul-Hamid, Jemilatu Gnuntimia and Yakubu, Abdul-Hayyu Yidana and Hlormah, Blessing and Zaazie, Maurice},
  title = {High False‐Positivity Rates of Widal Rapid Diagnostic Tests Compared to the Quantitative Tube Method for Salmonella typhi Detection in the Northern Region of Ghana},
  journal = {Tropical Medicine & International Health},
  year = {2026},
  doi = {10.1111/tmi.70159}
}