EUVIMEDEUVIMED entdecken
Validierungsstudie

Serotonin measurement by lab-on-a–contact lens in porcine and human tears

Minwoo Kim iD, Sang Won Lee iD, Chenguang Zhang iD, Wenyi Zeng, Liangshu Liu iD, Aliesha Danielle Garrett iD, Reihaneh Haghniaz, Dawn Meyer iD, Jianjun Chen, Juchen Guo iD, A Janet Tomiyama iD, Pete S Kollbaum iD und 1 weitere

Science Translational Medicine · 2026

DOI: 10.1126/scitranslmed.adv9538 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Science Translational Medicine, 2026. Verfasst von Minwoo Kim und 12 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Device Center, Terasaki Institute for Biomedical Innovation, Los Angeles, CA 91367, USA. Hauptthemen laut MEDLINE: Contact Lenses, Tears, Serotonin, Stress, Psychological. Die Arbeit nennt 110 Literaturangaben. Gefördert von: Brain and Behavior Research Foundation, Terasaki Institute for Biomedical Innovation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Stress-related endocrine responses are critical for understanding human performance and mental health. Conventional assessments rely heavily on subjective self-report questionnaires or invasive sampling such as venipuncture. Tears offer a noninvasive source of neurochemical biomarkers, including serotonin, a key regulator of stress and mood. However, real-time and continuous monitoring of tear serotonin has not yet been fully realized. Here, we present a reversible lab-on-a–contact lens platform that integrates a printable, stretchable ferrocene-based electrochemical sensor for in situ detection of serotonin in tear fluid. The device is fabricated on a soft hydrogel lens and uses an electrochemically refreshable redox surface to restore baseline between measurements. Calibration in artificial tears established a limit of detection of 72 picomolar and a dynamic range of 0.1 to 500 nanomolar. Function was maintained for more than 28 days in a tear-like environment and under repeated mechanical deformations (flipping, folding, stretching, and twisting), with stability confirmed by periodic redox cycling. Ocular safety and biocompatibility were demonstrated in a porcine eye model. In a chronic stress mouse model, tear serotonin concentrations inversely correlated with cortisol in both serum and tears, and a first-in-human pilot study further supported the relationship between tear serotonin and stress with off-line analysis by the lab-on-a–contact lens platform. This platform could enable applications in decentralized, noninvasive endocrine monitoring and holds promise as a clinically translatable tool for real-time mental health biomarker assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contact LensesTearsSerotoninStress, PsychologicalBiosensing TechniquesHumansAnimalsSwineBiomarkersMiceDisease Models, AnimalMaterials TestingPilot ProjectsMental HealthMaleFemaleAdultMiddle AgedAged

Substanzen

SerotoninBiomarkers

Autor:innen und Institutionen

  • Biomedical Device Center, Terasaki Institute for Biomedical Innovation, Los Angeles, CA 91367, USA.
  • Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea.
  • Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, China.
  • Department of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, CA 90089, USA.
  • School of Optometry, Indiana University, Bloomington, IN 47405, USA.
  • Department of Chemical and Environmental Engineering, University of California, Riverside, Riverside, CA 92521, USA.

ORCID-Profile: Minwoo Kim, Sang Won Lee, Chenguang Zhang, Liangshu Liu, Aliesha Danielle Garrett, Dawn Meyer, Juchen Guo, A Janet Tomiyama, Pete S Kollbaum, Yangzhi Zhu

Förderung

  • Brain and Behavior Research Foundation
  • Terasaki Institute for Biomedical Innovation

Zitieren

APA

Kim, M., Lee, S. W., Zhang, C., Zeng, W., Liu, L., Garrett, A. D., Haghniaz, R., Meyer, D., Chen, J., Guo, J., Tomiyama, A. J., Kollbaum, P. S., & Zhu, Y. (2026). Serotonin measurement by lab-on-a–contact lens in porcine and human tears. Science Translational Medicine. https://doi.org/10.1126/scitranslmed.adv9538

Vancouver

Kim M, Lee SW, Zhang C, Zeng W, Liu L, Garrett AD, et al. Serotonin measurement by lab-on-a–contact lens in porcine and human tears. Science Translational Medicine. 2026. doi:10.1126/scitranslmed.adv9538

BibTeX
@article{Kim2026,
  author = {Kim, Minwoo and Lee, Sang Won and Zhang, Chenguang and Zeng, Wenyi and Liu, Liangshu and Garrett, Aliesha Danielle and Haghniaz, Reihaneh and Meyer, Dawn and Chen, Jianjun and Guo, Juchen and Tomiyama, A Janet and Kollbaum, Pete S and Zhu, Yangzhi},
  title = {Serotonin measurement by lab-on-a–contact lens in porcine and human tears},
  journal = {Science Translational Medicine},
  year = {2026},
  doi = {10.1126/scitranslmed.adv9538}
}
Kostenlos starten →