Fachartikel in der Zeitschrift Science Translational Medicine, erschienen am 19.06.2024. Verfasst von Jue Deng und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA, 02139. Hauptthemen laut MEDLINE: Pacemaker, Artificial. Die Arbeit wurde bisher 53-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Current clinically used electronic implants, including cardiac pacing leads for epicardial monitoring and stimulation of the heart, rely on surgical suturing or direct insertion of electrodes to the heart tissue. These approaches can cause tissue trauma during the implantation and retrieval of the pacing leads, with the potential for bleeding, tissue damage, and device failure. Here, we report a bioadhesive pacing lead that can directly interface with cardiac tissue through physical and covalent interactions to support minimally invasive adhesive implantation and gentle on-demand removal of the device with a detachment solution. We developed 3D-printable bioadhesive materials for customized fabrication of the device by graft-polymerizing polyacrylic acid on hydrophilic polyurethane and mixing with poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) to obtain electrical conductivity. The bioadhesive construct exhibited mechanical properties similar to cardiac tissue and strong tissue adhesion, supporting stable electrical interfacing. Infusion of a detachment solution to cleave physical and covalent cross-links between the adhesive interface and the tissue allowed retrieval of the bioadhesive pacing leads in rat and porcine models without apparent tissue damage. Continuous and reliable cardiac monitoring and pacing of rodent and porcine hearts were demonstrated for 2 weeks with consistent capture threshold and sensing amplitude, in contrast to a commercially available alternative. Pacing and continuous telemetric monitoring were achieved in a porcine model. These findings may offer a promising platform for adhesive bioelectronic devices for cardiac monitoring and treatment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pacemaker, ArtificialAnimalsSwineRatsMonitoring, PhysiologicRats, Sprague-DawleyElectrodes, ImplantedAdhesivesPrinting, Three-DimensionalModels, Animal

Substanzen

Adhesives

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA, 02139.
  • Department of Thoracic Surgery, Mayo Clinic, Rochester, MN 55905, USA.
  • Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
  • Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen 518055, China.
  • Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905, USA.
  • Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, MN 55905, USA.

ORCID-Profile: Jue Deng, Jingjing Wu, Xiaoyu Chen, Tiffany L Sarrafian, Claudia E Varela, William Whyte, Chuan Fei Guo, Ellen T Roche, Leigh G Griffiths, Hyunwoo Yuk, Christoph S Nabzdyk, Xuanhe Zhao

Förderung

  • NHLBI NIH HHS

Zitieren

APA

Deng, J., Wu, J., Chen, X., Sarrafian, T. L., Varela, C. E., Whyte, W., Guo, C. F., Roche, E. T., Griffiths, L. G., Yuk, H., Nabzdyk, C. S., & Zhao, X. (2024). A bioadhesive pacing lead for atraumatic cardiac monitoring and stimulation in rodent and porcine models. Science Translational Medicine, 16(752). https://doi.org/10.1126/scitranslmed.ado9003

Vancouver

Deng J, Wu J, Chen X, Sarrafian TL, Varela CE, Whyte W, et al. A bioadhesive pacing lead for atraumatic cardiac monitoring and stimulation in rodent and porcine models. Science Translational Medicine. 2024;16(752). doi:10.1126/scitranslmed.ado9003

BibTeX
@article{Deng2024,
  author = {Deng, Jue and Wu, Jingjing and Chen, Xiaoyu and Sarrafian, Tiffany L and Varela, Claudia E and Whyte, William and Guo, Chuan Fei and Roche, Ellen T and Griffiths, Leigh G and Yuk, Hyunwoo and Nabzdyk, Christoph S and Zhao, Xuanhe},
  title = {A bioadhesive pacing lead for atraumatic cardiac monitoring and stimulation in rodent and porcine models},
  journal = {Science Translational Medicine},
  year = {2024},
  volume = {16},
  number = {752},
  doi = {10.1126/scitranslmed.ado9003}
}
Kostenlos starten →