EUVIMEDEUVIMED entdecken
Open Access

An intelligent, compact wearable pressure-strain combo sensor system for continuous fetal movement monitoring

Lim Wei Yap iD, Arie Levin iD, Yiwen Jiang iD, Duong Nhu iD, Shu Gong iD, Ritesh Warty, David Vera Anaya iD, Qinhao Li iD, Yan Lu, Rui Gao iD, Xin Zhang iD, Talha Ilyas iD und 13 weitere

Science Advances · 2025

DOI: 10.1126/sciadv.ady2661 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Science Advances, 2025. Verfasst von Lim Wei Yap und 24 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Faculty of Engineering, University of Sydney, Darlington, New South Wales 2008, Australia. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Fetal Monitoring, Fetal Movement. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Health and Medical Research Council, Jack Brockhoff foundation JBF, Snow Medical.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Continuous fetal movement monitoring in late pregnancy may improve fetal wellbeing and pregnancy outcomes. While fetal movements can be visualized with ultrasound, it is intermittent and limited to clinical settings. Inertial measurement units may enable at-home fetal monitoring but usually require a large-footprint, multisensor design. Here, we report smart, compact wearable pressure-strain combo sensors continuously monitoring fetal movements through maternal abdominal skin motions. In the 2D and 3D artificial abdomen systems, our octagonal-shaped gold nanowire–based strain sensor served as an isotropic sensor, enabling omnidirectional simulated “kicking load” detection within an area of ~77 (2D) and ~217 cm 2 (3D), while an interdigitated electrode–based pressure sensor showed highly sensitive localized load detection. Building upon these findings, we designed compact pressure- and strain-sensing integrated Band-Aids and tested on 59 pregnant women. We developed machine learning models to distinguish fetal from nonfetal movements with >90% accuracy in ultrasound-based validation studies. This AI-powered, Band-Aid–like sensing system offers potential as a compact, comfortable, and accurate continuous out-of-hospital fetal movement monitoring technology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesFetal MonitoringFetal MovementHumansFemalePregnancyPressureMachine LearningAdult

Autor:innen und Institutionen

  • School of Biomedical Engineering, Faculty of Engineering, University of Sydney, Darlington, New South Wales 2008, Australia.
  • Department of Chemical and Biological Engineering, Faculty of Engineering, Monash University, Clayton, Victoria 3168, Australia.
  • AIM for Health Lab, Faculty of Information Technology, Monash University, Clayton, Victoria, 3168, Australia.
  • Department of Obstetrics and Gynaecology, Monash University, Clayton, Victoria 3168, Australia.
  • Division of Perinatal Medicine, Faculty of Medicine and Health, University of Sydney, Kolling Institute, St. Leonards, NSW 2065, Australia.
  • Department of Obstetrics and Gynaecology, Royal North Shore Hospital, St. Leonards, NSW 2065, Australia.

ORCID-Profile: Lim Wei Yap, Arie Levin, Yiwen Jiang, Duong Nhu, Shu Gong, David Vera Anaya, Qinhao Li, Rui Gao, Xin Zhang, Talha Ilyas, Allison Thomas, Yuxin Zhang, Sharon A McCracken, Euan M Wallace, Arnold Lining Ju, Zongyuan Ge, Faezeh Marzbanrad, Wenlong Cheng

Förderung

  • National Health and Medical Research Council
  • Jack Brockhoff foundation JBF
  • Snow Medical
  • National Heart Foundation of Australia

Zitieren

APA

Yap, L. W., Levin, A., Jiang, Y., Nhu, D., Gong, S., Warty, R., Vera Anaya, D., Li, Q., Lu, Y., Gao, R., Zhang, X., Ilyas, T., Smith, V., Thomas, A., Wibrianto, A., Zhang, Y., Limas, J., A McCracken, S., Morris, J. M., …, & Cheng, W. (2025). An intelligent, compact wearable pressure-strain combo sensor system for continuous fetal movement monitoring. Science Advances. https://doi.org/10.1126/sciadv.ady2661

Vancouver

Yap LW, Levin A, Jiang Y, Nhu D, Gong S, Warty R, et al. An intelligent, compact wearable pressure-strain combo sensor system for continuous fetal movement monitoring. Science Advances. 2025. doi:10.1126/sciadv.ady2661

BibTeX
@article{Yap2025,
  author = {Yap, Lim Wei and Levin, Arie and Jiang, Yiwen and Nhu, Duong and Gong, Shu and Warty, Ritesh and Vera Anaya, David and Li, Qinhao and Lu, Yan and Gao, Rui and Zhang, Xin and Ilyas, Talha and Smith, Vinayak and Thomas, Allison and Wibrianto, Aswandi and Zhang, Yuxin and Limas, Jane and A McCracken, Sharon and Morris, Jonathan M and Mol, Ben W and Wallace, Euan M and Ju, Arnold Lining and Ge, Zongyuan and Marzbanrad, Faezeh and Cheng, Wenlong},
  title = {An intelligent, compact wearable pressure-strain combo sensor system for continuous fetal movement monitoring},
  journal = {Science Advances},
  year = {2025},
  doi = {10.1126/sciadv.ady2661}
}
Kostenlos starten →