Conformable ultrasound breast patch for deep tissue scanning and imaging
Science Advances · 28.07.2023 · 9 (30)
DOI: 10.1126/sciadv.adh5325 ↗Kurz gefasst
Fachartikel in der Zeitschrift Science Advances, erschienen am 28.07.2023. Verfasst von Wenya Du und 14 weiteren Autor:innen. Beteiligte Einrichtung: Media Lab, Massachusetts Institute of Technology, Cambridge, MA 02139, USA. Hauptthemen laut MEDLINE: Lead, Transducers. Die Arbeit wurde bisher 131-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Ultrasound is widely used for tissue imaging such as breast cancer diagnosis; however, fundamental challenges limit its integration with wearable technologies, namely, imaging over large-area curvilinear organs. We introduced a wearable, conformable ultrasound breast patch (cUSBr-Patch) that enables standardized and reproducible image acquisition over the entire breast with less reliance on operator training and applied transducer compression. A nature-inspired honeycomb-shaped patch combined with a phased array is guided by an easy-to-operate tracker that provides for large-area, deep scanning, and multiangle breast imaging capability. The in vitro studies and clinical trials reveal that the array using a piezoelectric crystal [Yb/Bi-Pb(In 1 /2 Nb 1/2 )O 3 -Pb(Mg 1/ 3 Nb 2/3 )O 3 -PbTiO 3 ] (Yb/Bi-PIN-PMN-PT) exhibits a sufficient contrast resolution (~3 dB) and axial/lateral resolutions of 0.25/1.0 mm at 30 mm depth, allowing the observation of small cysts (~0.3 cm) in the breast. This research develops a first-of-its-kind ultrasound technology for breast tissue scanning and imaging that offers a noninvasive method for tracking real-time dynamic changes of soft tissue.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Media Lab, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
- School of Opto-electronical Engineering, Xi'an Technological University, Xi'an 710021, China.
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
- Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA 02142, USA.
- Electronic Materials Research Laboratory, School of Electronic Science and Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
ORCID-Profile: Wenya Du, Lin Zhang, Dabin Lin, Sara Fernandez, Ikra Iftekhar Shuvo, Weiguo Liu, Fei Li, Anantha P Chandrakasan, Tolga Ozmen, Canan Dagdeviren
Zitieren
APA
Du, W., Zhang, L., Suh, E., Lin, D., Marcus, C., Ozkan, L., Ahuja, A., Fernandez, S., Shuvo, I. I., Sadat, D., Liu, W., Li, F., Chandrakasan, A. P., Ozmen, T., & Dagdeviren, C. (2023). Conformable ultrasound breast patch for deep tissue scanning and imaging. Science Advances, 9(30). https://doi.org/10.1126/sciadv.adh5325
Vancouver
Du W, Zhang L, Suh E, Lin D, Marcus C, Ozkan L, et al. Conformable ultrasound breast patch for deep tissue scanning and imaging. Science Advances. 2023;9(30). doi:10.1126/sciadv.adh5325
BibTeX
@article{Du2023,
author = {Du, Wenya and Zhang, Lin and Suh, Emma and Lin, Dabin and Marcus, Colin and Ozkan, Lara and Ahuja, Avani and Fernandez, Sara and Shuvo, Ikra Iftekhar and Sadat, David and Liu, Weiguo and Li, Fei and Chandrakasan, Anantha P and Ozmen, Tolga and Dagdeviren, Canan},
title = {Conformable ultrasound breast patch for deep tissue scanning and imaging},
journal = {Science Advances},
year = {2023},
volume = {9},
number = {30},
doi = {10.1126/sciadv.adh5325}
}