EUVIMEDEUVIMED entdecken
Vergleichsstudie

Agreement Between Lab- and Field-Derived Sprint Power Reserve in U23 Elite Cyclists

Peter Leo iD, Iñigo Mujika iD

International Journal of Sports Physiology and Performance · 01.02.2026 · 21 (2) · 294-301

DOI: 10.1123/ijspp.2025-0256 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift International Journal of Sports Physiology and Performance, erschienen am 01.02.2026. Verfasst von Peter Leo und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sport Science, University of Innsbruck, Innsbruck, Austria. Hauptthemen laut MEDLINE: Bicycling, Exercise Test, Athletic Performance. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 66 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The aim of this study was to evaluate the predictive ability of the sprint power reserve model in the extreme and severe intensity domains by comparing predictions from laboratory and field conditions with field-recorded mean maximum power outputs (MMPs).

Methods

Ten male U23 (under 23 y of age) cyclists participated in this study (height 182.9 [4.7] cm; body mass 71.4 [6.5] kg; 74.2 [3.1] mL·kg −1 ·min −1 ). Participants completed an incremental graded exercise test and a 10-second sprint test in the laboratory, as well as a 3-minute field test and a 10-second sprint test in the field (Pmax FIELD ). Predictions from laboratory (PRED LAB ) and field (PRED FIELD ) were compared via Bland–Altman plots with MMP over 15-, 30-, 60-, 90-, 120-, and 150-second durations.

Results

No significant differences were found between the lab and field 10-second sprint tests, nor between the 3-minute field test and the peak power achieved in the incremental laboratory test (P GXT , P > .05). The sprint-power-reserve time constant k = 0.027 revealed the best fit to MMP ( R 2 = .98; P ≤ .001). Apart from a difference between MMP and PRED LAB for 90-second power output (Δ = 68 W, P = .04), no further differences were found ( P > .05). All predictions of PRED LAB and PRED FIELD of MMP were within 95% limits of agreement, except the 150-second duration for PRED FIELD .

Discussion

High-intensity-power-output predictions of the sprint power reserve model derived from laboratory and field conditions present similar levels of reliability, and both can be used by practitioners with confidence.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BicyclingExercise TestAthletic PerformanceHumansMaleOxygen ConsumptionYoung Adult

Stichwörter der Autor:innen

cyclingmodelingpower outputprediction

Autor:innen und Institutionen

  • Department of Sport Science, University of Innsbruck, Innsbruck, Austria.
  • UniSA Allied Health & Human Performance, University of South Australia, Adelaide, SA, Australia.
  • Department of Physiology, Faculty of Medicine and Nursing, University of the Basque Country UPV/EHU, Leioa, Basque Country.
  • Exercise Science Laboratory, School of Kinesiology, Faculty of Medicine, Universidad Finis Terrae, Santiago, Chile.

ORCID-Profile: Peter Leo, Iñigo Mujika

Zitieren

APA

Leo, P., & Mujika, I. (2026). Agreement Between Lab- and Field-Derived Sprint Power Reserve in U23 Elite Cyclists. International Journal of Sports Physiology and Performance, 21(2), 294-301. https://doi.org/10.1123/ijspp.2025-0256

Vancouver

Leo P, Mujika I. Agreement Between Lab- and Field-Derived Sprint Power Reserve in U23 Elite Cyclists. International Journal of Sports Physiology and Performance. 2026;21(2):294-301. doi:10.1123/ijspp.2025-0256

BibTeX
@article{Leo2026,
  author = {Leo, Peter and Mujika, Iñigo},
  title = {Agreement Between Lab- and Field-Derived Sprint Power Reserve in U23 Elite Cyclists},
  journal = {International Journal of Sports Physiology and Performance},
  year = {2026},
  volume = {21},
  number = {2},
  pages = {294--301},
  doi = {10.1123/ijspp.2025-0256}
}
Kostenlos starten →