Reliability of 10- and 30-Second Tethered Swimming Tests in Highly Trained Swimmers: Influence of Swimming Specialty, Sex, Performance Level, and Evaluator
International Journal of Sports Physiology and Performance · 01.05.2026 · 21 (5) · 648-655
DOI: 10.1123/ijspp.2025-0203 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Sports Physiology and Performance, erschienen am 01.05.2026. Verfasst von Marien Couvertier und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institut Prime, UPR 3346, CNRS-University of Poitiers-ISAE-ENSMA, Poitiers, France. Hauptthemen laut MEDLINE: Swimming, Athletic Performance, Exercise Test. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 68 Literaturangaben.
Abstract (Originalsprache)
Purpose
The tethered swimming test is relevant for the longitudinal monitoring of swimmers. However, for accurate interpretation of observed variations over time, understanding the reliability of the test and the factors influencing it is crucial. This study aimed to assess the absolute and relative reliability of parameters derived from 10- and 30-second front-crawl-tethered swimming tests by considering swimming specialty, sex, and performance level. Output variables resulting from manual stroke cycle segmentation were examined to evaluate interevaluator reliability.
Methods
Twenty-one highly trained swimmers performed the 2 specific time-based tests over 3 consecutive days. Relative and absolute reliability were assessed using the intraclass correlation coefficient and standard error of measurement, respectively.
Results
Mean force, peak force, and impulse demonstrated high reliability (intraclass correlation coefficient > .86 and .73 for 10- and 30-s tests, respectively). Fatigue index, performance decrement, and rate of performance decline exhibited varying reliability from poor to high. These results were unaffected by swimming specialty, sex, performance level, or evaluator.
Conclusion
The findings indicate that 10- and 30-second front-crawl tethered swimming tests are highly reliable. Mean force, peak force, and impulse emerge as the most reliable parameters, regardless of the swimming specialty, sex, performance level, or evaluator.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institut Prime, UPR 3346, CNRS-University of Poitiers-ISAE-ENSMA, Poitiers, France.
- Laboratory MOVE-UR 20296-University of Poitiers, Poitiers, France.
- Laboratory Sport, Expertise and Performance, INSEP, Paris, France.
- Fédération Française de Natation, Paris, France.
ORCID-Profile: Marien Couvertier, Quentin Bretonneau, Tony Monnet, Robin Pla, Laurent Bosquet, Arnaud Decatoire
Zitieren
APA
Couvertier, M., Bretonneau, Q., Monnet, T., Samson, M., Morales-Artacho, A., Pla, R., Bosquet, L., Decatoire, A., & D-Day Consortium (2026). Reliability of 10- and 30-Second Tethered Swimming Tests in Highly Trained Swimmers: Influence of Swimming Specialty, Sex, Performance Level, and Evaluator. International Journal of Sports Physiology and Performance, 21(5), 648-655. https://doi.org/10.1123/ijspp.2025-0203
Vancouver
Couvertier M, Bretonneau Q, Monnet T, Samson M, Morales-Artacho A, Pla R, et al. Reliability of 10- and 30-Second Tethered Swimming Tests in Highly Trained Swimmers: Influence of Swimming Specialty, Sex, Performance Level, and Evaluator. International Journal of Sports Physiology and Performance. 2026;21(5):648-655. doi:10.1123/ijspp.2025-0203
BibTeX
@article{Couvertier2026,
author = {Couvertier, Marien and Bretonneau, Quentin and Monnet, Tony and Samson, Mathias and Morales-Artacho, Antonio and Pla, Robin and Bosquet, Laurent and Decatoire, Arnaud and D-Day Consortium, D-Day Consortium},
title = {Reliability of 10- and 30-Second Tethered Swimming Tests in Highly Trained Swimmers: Influence of Swimming Specialty, Sex, Performance Level, and Evaluator},
journal = {International Journal of Sports Physiology and Performance},
year = {2026},
volume = {21},
number = {5},
pages = {648--655},
doi = {10.1123/ijspp.2025-0203}
}