Validating the Use of Continuous Glucose Monitors With Nondiabetic Recreational Runners

Lesley J Mason iD, Timothy Hartwig iD, David Greene iD

International Journal of Sports Physiology and Performance · 2024

DOI: 10.1123/ijspp.2024-0102 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift International Journal of Sports Physiology and Performance, 2024. Verfasst von Lesley J Mason und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Health Sciences, Australian Catholic University, Strathfield, NSW, Australia. Hauptthemen laut MEDLINE: Running, Blood Glucose, Blood Glucose Self-Monitoring. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Continuous glucose monitors (CGMs) are becoming increasingly popular among endurance athletes despite unconfirmed accuracy. We assessed the concurrent validity of the FreeStyle Libre 2 worn on 2 different sites at rest, during steady-state running, and postprandial.

Methods

Thirteen nondiabetic, well-trained recreational runners (age = 40 [8] y, maximal aerobic oxygen consumption = 46.1 [6.4] mL·kg –1 ·min –1 ) wore a CGM on the upper arm and chest while treadmill running for 30, 60, and 90 minutes at intensities corresponding to 50%, 60%, and 70% of maximal aerobic oxygen consumption, respectively. Glucose was measured by manually scanning CGMs and obtaining a finger-prick capillary blood glucose sample. Mean absolute relative difference, time in range, and continuous glucose Clarke error grid analysis were used to compare paired CGM and blood glucose readings.

Results

Across all intensities of steady-state running, we found a mean absolute relative difference of 13.8 (10.9) for the arm and 11.4 (9.0) for the chest. The coefficient of variation exceeded 70%. Approximately 47% of arm and 50% of chest paired glucose measurements had an absolute difference ≤10%. Continuous glucose Clarke error grid analysis indicated 99.8% (arm) and 99.6% (chest) CGM data fell in clinically acceptable zones A and B. Time-in-range analysis showed reduced accuracy at lower glucose levels. However, CGMs accurately detected trends in mean glucose readings over time.

Conclusions

CGMs are not valid for point glucose monitoring but appear to be valid for monitoring glucose trends during steady-state exercise. Accuracy is similar for arm and chest. Further research is needed to determine whether CGMs can detect important events such as hypoglycemia during exercise.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RunningBlood GlucoseBlood Glucose Self-MonitoringHumansAdultMaleOxygen ConsumptionFemaleReproducibility of ResultsPostprandial PeriodArmExercise TestMiddle Aged

Stichwörter der Autor:innen

accuracyathlete monitoringendurance exerciseglucose metabolismwearables

Substanzen

Blood Glucose

Autor:innen und Institutionen

  • Faculty of Health Sciences, Australian Catholic University, Strathfield, NSW, Australia.
  • School of Exercise Science, Australian Catholic University, Strathfield, NSW, Australia.

ORCID-Profile: Lesley J Mason, Timothy Hartwig, David Greene

Zitieren

APA

Mason, L. J., Hartwig, T., & Greene, D. (2024). Validating the Use of Continuous Glucose Monitors With Nondiabetic Recreational Runners. International Journal of Sports Physiology and Performance. https://doi.org/10.1123/ijspp.2024-0102

Vancouver

Mason LJ, Hartwig T, Greene D. Validating the Use of Continuous Glucose Monitors With Nondiabetic Recreational Runners. International Journal of Sports Physiology and Performance. 2024. doi:10.1123/ijspp.2024-0102

BibTeX
@article{Mason2024,
  author = {Mason, Lesley J and Hartwig, Timothy and Greene, David},
  title = {Validating the Use of Continuous Glucose Monitors With Nondiabetic Recreational Runners},
  journal = {International Journal of Sports Physiology and Performance},
  year = {2024},
  doi = {10.1123/ijspp.2024-0102}
}
Kostenlos starten →