EUVIMEDEUVIMED entdecken
Crossref

Continuous Glucose Monitoring Underreports Blood Glucose During a Simulated Ultraendurance Run in Eumenorrheic Female Runners

Andrew Dole iD, Stacy Sims iD, Han Gan iD, Nic Gill, Martyn Beaven iD

International Journal of Sports Physiology and Performance · 2025

DOI: 10.1123/ijspp.2024-0068 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Sports Physiology and Performance, 2025. Verfasst von Andrew Dole und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Health, Engineering, Computing and Science, Te Huataki Waiora School of Health, University of Waikato, Tauranga, New Zealand. Hauptthemen laut MEDLINE: Running, Blood Glucose, Menstrual Cycle, Blood Glucose Self-Monitoring. Die Arbeit nennt 55 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Continuous-glucose-monitoring (CGM) sensors provide near-real-time glucose data and have been introduced commercially as a tool to inform nutrition decisions. The aim of this pilot study was to explore how factors such as the menstrual phase, extended running duration, and carbohydrates affect CGM outcomes among trained eumenorrheic females in an outdoor simulated ultraendurance running event.

Methods

Twelve experienced female ultrarunners (age 39 [6] y) participated in this crossover study. Participants completed an ultraendurance simulation run of 4 hours in the midfollicular and midluteal phases of their menstrual cycle, which consisted of a 3-hour fasted outdoor run (FASTED) followed by a 1-hour treadmill run (TREAD), where 3 standardized 20-g oral glucose doses were provided.

Results

Using a mixed linear model, the menstrual phase was statistically significant for differences in glucose measurements from CGM compared with capillary glucose sampling during TREAD ( P = .02) but not FASTED. Additionally, the CGM sensor reported glucose levels with an average of −0.43 mmol·L −1 (95% CI, − 0.86 to −0.005) and −1.02 mmol·L −1 (95% CI, −1.63 to −0.42) lower in fasted and fed scenarios, respectively, when compared with capillary glucose.

Conclusion

CGM underreports capillary glucose during fasted and fed exercise. Factors contributing to this underreporting between the sampling methods (CGM vs capillary) were dependent on a combination of exogenous glucose availability, individual biological differences, and the menstrual phase.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RunningBlood GlucoseMenstrual CycleBlood Glucose Self-MonitoringPhysical EnduranceHumansFemaleCross-Over StudiesAdultPilot ProjectsFastingContinuous Glucose Monitoring

Stichwörter der Autor:innen

continuous glucose monitoringfemale athleteinterstitialmenstrual cyclemetabolism

Substanzen

Blood Glucose

Autor:innen und Institutionen

  • Division of Health, Engineering, Computing and Science, Te Huataki Waiora School of Health, University of Waikato, Tauranga, New Zealand.
  • Adams Centre for High Performance, Mount Maunganui, New Zealand.
  • Sports Performance Research Institute of New Zealand SPRINZ, Auckland University of Technology, Auckland, New Zealand.
  • Stanford Lifestyle Medicine, Stanford University, Palo Alto, CA, USA.
  • Department of Mathematics, University of Waikato, Hamilton, New Zealand.

ORCID-Profile: Andrew Dole, Stacy Sims, Han Gan, Martyn Beaven

Zitieren

APA

Dole, A., Sims, S., Gan, H., Gill, N., & Beaven, M. (2025). Continuous Glucose Monitoring Underreports Blood Glucose During a Simulated Ultraendurance Run in Eumenorrheic Female Runners. International Journal of Sports Physiology and Performance. https://doi.org/10.1123/ijspp.2024-0068

Vancouver

Dole A, Sims S, Gan H, Gill N, Beaven M. Continuous Glucose Monitoring Underreports Blood Glucose During a Simulated Ultraendurance Run in Eumenorrheic Female Runners. International Journal of Sports Physiology and Performance. 2025. doi:10.1123/ijspp.2024-0068

BibTeX
@article{Dole2025,
  author = {Dole, Andrew and Sims, Stacy and Gan, Han and Gill, Nic and Beaven, Martyn},
  title = {Continuous Glucose Monitoring Underreports Blood Glucose During a Simulated Ultraendurance Run in Eumenorrheic Female Runners},
  journal = {International Journal of Sports Physiology and Performance},
  year = {2025},
  doi = {10.1123/ijspp.2024-0068}
}
Kostenlos starten →