EUVIMEDEUVIMED entdecken
Crossref

Optimizing Wearable Device and Testing Parameters to Monitor Running-Stride Long-Range Correlations for Fatigue Management in Field Settings

Joel T Fuller iD, Dominic Thewlis iD, Jodie A Wills iD, Jonathan D Buckley iD, John B Arnold iD, Eoin Doyle iD, Tim L A Doyle iD, Clint R Bellenger iD

International Journal of Sports Physiology and Performance · 2024

DOI: 10.1123/ijspp.2023-0186 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Sports Physiology and Performance, 2024. Verfasst von Joel T Fuller und 7 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, NSW, Australia. Hauptthemen laut MEDLINE: Running, Wearable Electronic Devices. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

There are important methodological considerations for translating wearable-based gait-monitoring data to field settings. This study investigated different devices’ sampling rates, signal lengths, and testing frequencies for athlete monitoring using dynamical systems variables.

Methods

Secondary analysis of previous wearables data (N = 10 runners) from a 5-week intensive training intervention investigated impacts of sampling rate (100–2000 Hz) and signal length (100–300 strides) on detection of gait changes caused by intensive training. Primary analysis of data from 13 separate runners during 1 week of field-based testing determined day-to-day stability of outcomes using single-session data and mean data from 2 sessions. Stride-interval long-range correlation coefficient α from detrended fluctuation analysis was the gait outcome variable.

Results

Stride-interval α reduced at 100- and 200- versus 300- to 2000-Hz sampling rates (mean difference: −.02 to −.08; P ≤ .045) and at 100- compared to 200- to 300-stride signal lengths (mean difference: −.05 to −.07; P < .010). Effects of intensive training were detected at 100, 200, and 400 to 2000 Hz ( P ≤ .043) but not 300 Hz ( P = .069). Within-athlete α variability was lower using 2-session mean versus single-session data (smallest detectable change: .13 and .22, respectively).

Conclusions

Detecting altered gait following intensive training was possible using 200 to 300 strides and a 100-Hz sampling rate, although 100 and 200 Hz underestimated α compared to higher rates. Using 2-session mean data lowers smallest detectable change values by nearly half compared to single-session data. Coaches, runners, and researchers can use these findings to integrate wearable-device gait monitoring into practice using dynamic systems variables.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RunningWearable Electronic DevicesHumansGaitAthletesFatigueBiomechanical Phenomena

Stichwörter der Autor:innen

accelerometerbiomechanicsmotor controlovertrainingsampling rate

Autor:innen und Institutionen

  • Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, NSW, Australia.
  • Biomechanics, Physical Performance, and Exercise Research Group, Macquarie University, Sydney, NSW, Australia.
  • Adelaide Medical School, University of Adelaide, Adelaide, SA, Australia.
  • Alliance for Research in Exercise, Nutrition and Activity (ARENA), UniSA Allied Health and Human Performance Unit, University of South Australia, Adelaide, SA, Australia.

ORCID-Profile: Joel T Fuller, Dominic Thewlis, Jodie A Wills, Jonathan D Buckley, John B Arnold, Eoin Doyle, Tim L A Doyle, Clint R Bellenger

Zitieren

APA

Fuller, J. T., Thewlis, D., Wills, J. A., Buckley, J. D., Arnold, J. B., Doyle, E., Doyle, T. L. A., & Bellenger, C. R. (2024). Optimizing Wearable Device and Testing Parameters to Monitor Running-Stride Long-Range Correlations for Fatigue Management in Field Settings. International Journal of Sports Physiology and Performance. https://doi.org/10.1123/ijspp.2023-0186

Vancouver

Fuller JT, Thewlis D, Wills JA, Buckley JD, Arnold JB, Doyle E, et al. Optimizing Wearable Device and Testing Parameters to Monitor Running-Stride Long-Range Correlations for Fatigue Management in Field Settings. International Journal of Sports Physiology and Performance. 2024. doi:10.1123/ijspp.2023-0186

BibTeX
@article{Fuller2024,
  author = {Fuller, Joel T and Thewlis, Dominic and Wills, Jodie A and Buckley, Jonathan D and Arnold, John B and Doyle, Eoin and Doyle, Tim L A and Bellenger, Clint R},
  title = {Optimizing Wearable Device and Testing Parameters to Monitor Running-Stride Long-Range Correlations for Fatigue Management in Field Settings},
  journal = {International Journal of Sports Physiology and Performance},
  year = {2024},
  doi = {10.1123/ijspp.2023-0186}
}
Kostenlos starten →