EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Instrumenting Parkrun: Usefulness and Validity of Inertial Sensors

Rachel Mason iD, Yunus Celik, Gill Barry, Alan Godfrey iD, Samuel Stuart

Sensors · 2024

DOI: 10.3390/s25010030 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Rachel Mason und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne NE1 8ST, UK. Hauptthemen laut MEDLINE: Running, Gait, Accelerometry, Wearable Electronic Devices. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: DANU Sports Ltd., Northumbria University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The analysis of running gait has conventionally taken place within an expensive and restricted laboratory space, with wearable technology offering a practical, cost-effective, and unobtrusive way to examine running gait in more natural environments. This pilot study presents a wearable inertial measurement unit (IMU) setup for the continuous analysis of running gait during an outdoor parkrun (i.e., 5 km). The study aimed to (1) provide analytical validation of running gait measures compared to time- and age-graded performance and (2) explore performance validation. Ten healthy adults (7 females, 3 males, mean age 37.2 ± 11.7 years) participated. The participants wore Axivity AX6 IMUs on the talus joint of each foot, recording tri-axial accelerometer and gyroscope data at 200 Hz. Temporal gait characteristics—gait cycle, ground contact time, swing time, and duty factor—were extracted using zero-crossing algorithms. The data were analyzed for correlations between the running performance, foot strike type, and fatigue-induced changes in temporal gait characteristics. Strong correlations were found between the performance time and both the gait cycle and ground contact time, with weak correlations for foot strike types. The analysis of asymmetry and fatigue highlighted modest changes in gait as fatigue increased, but no significant gender differences were found. This setup demonstrates potential for in-field gait analysis for running, providing insights for performance and injury prevention strategies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RunningGaitAccelerometryWearable Electronic DevicesGait AnalysisHumansMaleFemaleAdultMiddle AgedBiomechanical PhenomenaAlgorithms

Stichwörter der Autor:innen

IMUaccelerometergaitrunningwearable technology

Autor:innen und Institutionen

  • Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne NE1 8ST, UK.
  • Department of Computer and Information Sciences, Northumbria University, Newcastle upon Tyne NE1 8ST, UK.
  • Department of Neurology, Oregon Health and Science University, Portland, OR 97239, USA.

ORCID-Profile: Rachel Mason, Alan Godfrey

Förderung

  • DANU Sports Ltd.
  • Northumbria University

Zitieren

APA

Mason, R., Celik, Y., Barry, G., Godfrey, A., & Stuart, S. (2024). Instrumenting Parkrun: Usefulness and Validity of Inertial Sensors. Sensors. https://doi.org/10.3390/s25010030

Vancouver

Mason R, Celik Y, Barry G, Godfrey A, Stuart S. Instrumenting Parkrun: Usefulness and Validity of Inertial Sensors. Sensors. 2024. doi:10.3390/s25010030

BibTeX
@article{Mason2024,
  author = {Mason, Rachel and Celik, Yunus and Barry, Gill and Godfrey, Alan and Stuart, Samuel},
  title = {Instrumenting Parkrun: Usefulness and Validity of Inertial Sensors},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s25010030}
}
Kostenlos starten →