Accuracy of Heart-Rate-Recovery Parameters Assessed From a Wrist-Worn Photoplethysmography Monitor (Polar Unite)
International Journal of Sports Physiology and Performance · 01.01.2024 · 19 (1) · 13-18
DOI: 10.1123/ijspp.2023-0120 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Sports Physiology and Performance, erschienen am 01.01.2024. Verfasst von Quentin Bretonneau und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculté des sciences du sport, Laboratoire MOVE (UR 20296), Université de Poitiers, Poitiers, France. Hauptthemen laut MEDLINE: Wrist, Photoplethysmography. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
Purpose
The accuracy of heart rate (HR) measured with a wrist-worn photoplethysmography (PPG) monitor is altered during rest–exercise and exercise–rest transitions, which questions the validity of postexercise HR-recovery (HRR) parameters estimated from this device.
Methods
Thirty participants (50% female) randomly performed two 13-minute sequences (3′ rest, 5′ submaximal-intensity exercise, and 5′ passive recovery) on treadmill and bicycle ergometers. HR was measured concomitantly with a 10-lead electrocardiogram (ECG) and a wrist-worn PPG monitor (Polar Unite). HRR was assessed by calculating Δ60 (the difference between HR during exercise and HR 60 s after exercise cessation) and by fitting HRR data into a monoexponential model.
Results
By focusing on Δ60 and τ (the time constant of the monoexponential curve), levels of association ( r ) of the Unite versus the 10-lead ECG were high to very high (.73 < r < .93), and coefficients of variation were >20% (in absolute value), except for Δ60 in the bicycle ergometer condition (11.7%). In 97% of cases, the decrease in HR after exercise appeared later with the Unite. By adjusting the time window used for the analysis according to this time lag, coefficients of variation of Δ60 decreased below 10% in the bicycle ergometer condition.
Conclusions
If a wrist-worn PPG monitor is used to assess HRR, we recommend performing the submaximal-intensity exercise on a bicycle ergometer and focusing on Δ60. Furthermore, to obtain a more accurate Δ60, the time lag between the end of the exercise and the effective decrease in HR should also be considered before the calculation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculté des sciences du sport, Laboratoire MOVE (UR 20296), Université de Poitiers, Poitiers, France.
ORCID-Profile: Quentin Bretonneau, Laurent Bosquet
Zitieren
APA
Bretonneau, Q., Peruque-Gayou, E., Wolfs, E., & Bosquet, L. (2024). Accuracy of Heart-Rate-Recovery Parameters Assessed From a Wrist-Worn Photoplethysmography Monitor (Polar Unite). International Journal of Sports Physiology and Performance, 19(1), 13-18. https://doi.org/10.1123/ijspp.2023-0120
Vancouver
Bretonneau Q, Peruque-Gayou E, Wolfs E, Bosquet L. Accuracy of Heart-Rate-Recovery Parameters Assessed From a Wrist-Worn Photoplethysmography Monitor (Polar Unite). International Journal of Sports Physiology and Performance. 2024;19(1):13-18. doi:10.1123/ijspp.2023-0120
BibTeX
@article{Bretonneau2024,
author = {Bretonneau, Quentin and Peruque-Gayou, Etienne and Wolfs, Etienne and Bosquet, Laurent},
title = {Accuracy of Heart-Rate-Recovery Parameters Assessed From a Wrist-Worn Photoplethysmography Monitor (Polar Unite)},
journal = {International Journal of Sports Physiology and Performance},
year = {2024},
volume = {19},
number = {1},
pages = {13--18},
doi = {10.1123/ijspp.2023-0120}
}