EUVIMEDEUVIMED entdecken
Crossref

Phase-coherence volumetric ultrasonic imaging of full matrix capture data using row-column-addressed array

Xuan Li iD, Lishuai Liu iD, Shijun Wang iD, Yuncheng Zhang, Rui Zhang, Yanxun Xiang iD, Fu-Zhen Xuan iD

The Journal of the Acoustical Society of America · 01.08.2026 · 160 (2) · 951-961

DOI: 10.1121/10.0044505 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, online erschienen am 03.08.2026. Verfasst von Xuan Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Shanghai Key Laboratory of Intelligent Sensing and Detection Technology, School of Mechanical and Power Engineering, East China University of Science…. Die Arbeit nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental and Interdisciplinary Disciplines Breakthrough Plan of the Ministry of Education of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Row-column-addressed (RCA) arrays enable three-dimensional (3D) volumetric ultrasonic imaging with significantly reduced channel count and system complexity compared with fully addressed planar arrays. However, their imaging performance is limited by steering-angle-dependent acoustic fields and receive sensitivity, which can lead to degraded off-axis resolution, elevated sidelobes, and ghost artifacts. To address these challenges, this study proposes a systematic phase-coherence-based imaging framework for enhancing 3D volumetric imaging quality using full matrix capture data acquired with RCA arrays. A suite of 3D imaging algorithms is developed based on different statistical phase-coherence measures, enabling effective suppression of incoherent contributions in the beamformed signals. Experimental results demonstrate that phase-coherence weighting substantially improves contrast ratio and reduces imaging artifacts compared with conventional delay-and-sum based approaches. Among the evaluated methods, the sign coherence factor achieves a favorable balance between computational efficiency and imaging performance while effectively mitigating near-field effects. Overall, these results demonstrate the feasibility of achieving high-quality 3D volumetric ultrasonic imaging with RCA arrays and highlight the potential of phase-coherence-based strategies to provide robust and interpretable volumetric reconstructions for a broad range of ultrasonic imaging applications.

Autor:innen und Institutionen

  • Shanghai Key Laboratory of Intelligent Sensing and Detection Technology, School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai 200237, China.
  • Gansu Electric Power Corporation, State Grid, Lanzhou 730050, China.
  • Eintik Technologies (Shanghai) Co., Ltd., Shanghai 201814, China.

ORCID-Profile: Xuan Li, Lishuai Liu, Shijun Wang, Yanxun Xiang, Fu-Zhen Xuan

Förderung

  • National Natural Science Foundation of China
  • Fundamental and Interdisciplinary Disciplines Breakthrough Plan of the Ministry of Education of China

Zitieren

APA

Li, X., Liu, L., Wang, S., Zhang, Y., Zhang, R., Xiang, Y., & Xuan, F. Z. (2026). Phase-coherence volumetric ultrasonic imaging of full matrix capture data using row-column-addressed array. The Journal of the Acoustical Society of America, 160(2), 951-961. https://doi.org/10.1121/10.0044505

Vancouver

Li X, Liu L, Wang S, Zhang Y, Zhang R, Xiang Y, et al. Phase-coherence volumetric ultrasonic imaging of full matrix capture data using row-column-addressed array. The Journal of the Acoustical Society of America. 2026;160(2):951-961. doi:10.1121/10.0044505

BibTeX
@article{Li2026,
  author = {Li, Xuan and Liu, Lishuai and Wang, Shijun and Zhang, Yuncheng and Zhang, Rui and Xiang, Yanxun and Xuan, Fu-Zhen},
  title = {Phase-coherence volumetric ultrasonic imaging of full matrix capture data using row-column-addressed array},
  journal = {The Journal of the Acoustical Society of America},
  year = {2026},
  volume = {160},
  number = {2},
  pages = {951--961},
  doi = {10.1121/10.0044505}
}
Kostenlos starten →