Bias-Switchable Row–Column Array Imaging Using Fast Orthogonal Row–Column Electronic Scanning (FORCES) Compared With Conventional Row–Column Array Imaging
IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control · 2026 · 6 · 340-351
DOI: 10.1109/ojuffc.2026.3749063 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control, 2026. Verfasst von Randy N Palamar und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 2R3, Canada. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institutes of Health, Alberta Innovates, Mitacs.
Abstract (Originalsprache)
Row-Column Arrays (RCAs) offer an attractive alternative to fully wired 2D-arrays for 3D-ultrasound, due to their greatly simplified wiring. However, conventional RCAs face challenges related to their long elements. These include an inability to image beyond the shadow of the aperture and an inability to focus in both transmit and receive for desired scan planes. To address these limitations, we recently developed bias-switchable RCAs, also known as Top Orthogonal to Bottom Electrode (TOBE) arrays. These arrays provide novel opportunities to read out from every element of the array and achieve high-quality images. While TOBE arrays and their associated imaging schemes have shown promise, they have not yet been directly compared experimentally to conventional RCA imaging techniques. This study aims to provide such a comparison, demonstrating superior B-scan and volumetric images from two electrostrictive relaxor TOBE arrays, using a method called Fast Orthogonal Row-Column Electronic scanning (FORCES), compared to conventional RCA imaging schemes, including Tilted Plane Wave (TPW) compounding and Virtual Line Source (VLS) imaging. The study quantifies resolution and Generalized Contrast to Noise Ratio (gCNR) in phantoms, and also demonstrates volumetric acquisitions in phantom and animal models.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 2R3, Canada.
- School of Biomedical Engineering, Dalhousie University, Halifax, NS B3H 4R2, Canada.
ORCID-Profile: Randy N Palamar, Darren Dahunsi, Negar Majidi, Roger Zemp
Förderung
- National Institutes of Health
- Alberta Innovates
- Mitacs
- CliniSonix Inc.
- Natural Sciences and Engineering Research Council of Canada
- Alberta Cancer Foundation
- Mary Johnston Family Melanoma Grant
- Government of Alberta Cancer Research for Screening and Prevention Fund
Zitieren
APA
Palamar, R. N., Sobhani, M., Dahunsi, D., Majidi, N., Ilkhechi, A. K., Wang, J., Brown, J., & Zemp, R. (2026). Bias-Switchable Row–Column Array Imaging Using Fast Orthogonal Row–Column Electronic Scanning (FORCES) Compared With Conventional Row–Column Array Imaging. IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control, 6, 340-351. https://doi.org/10.1109/ojuffc.2026.3749063
Vancouver
Palamar RN, Sobhani M, Dahunsi D, Majidi N, Ilkhechi AK, Wang J, et al. Bias-Switchable Row–Column Array Imaging Using Fast Orthogonal Row–Column Electronic Scanning (FORCES) Compared With Conventional Row–Column Array Imaging. IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control. 2026;6:340-351. doi:10.1109/ojuffc.2026.3749063
BibTeX
@article{Palamar2026,
author = {Palamar, Randy N and Sobhani, Mohammad and Dahunsi, Darren and Majidi, Negar and Ilkhechi, Afshin Kashani and Wang, Joy and Brown, Jeremy and Zemp, Roger},
title = {Bias-Switchable Row–Column Array Imaging Using Fast Orthogonal Row–Column Electronic Scanning (FORCES) Compared With Conventional Row–Column Array Imaging},
journal = {IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control},
year = {2026},
volume = {6},
pages = {340--351},
doi = {10.1109/ojuffc.2026.3749063}
}
EUVIMED