EUVIMEDEUVIMED entdecken
Crossref

Performance evaluation of portable viscoelastic response ultrasound imaging system

Md Walid Hassan, Damian Cacko, Ziemowit Klimonda, Md Murad Hossain

The Journal of the Acoustical Society of America · 01.10.2025 · 158 (4_Supplement) · A429-A429

DOI: 10.1121/10.0041395 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, erschienen am 01.10.2025. Verfasst von Md Walid Hassan und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

VisR ultrasound, an “on-axis” acoustic radiation force-based elastography method, qualitatively assesses tissue viscoelastic properties from peak displacement (PD), relative elasticity (RE), and relative viscosity (RV) parameters. In this work, VisR was implemented on the portable us4R-lite + platform (us4us, Poland) with an L7-4 linear array (4.33 MHz excitation pulse with 70 μs duration and two cycles 5.9 MHz tracking pulse) and evaluated by imaging 4.7, 8.6, 34.0, and 70.9 kPa inclusions (6.49 mm diameter) embedded in a 16.7-kPa background of industry-standard elasticity phantom by varying the focal depth at 30 and 37 mm. (PD, RE, and RV)-derived contrast-to-noise ratio (CNR) of four inclusions was (3.45,1.54, 3.43), (3.71, 1.16, 3.12), (1.73, 1.03, 1.39), and (3.24, 1.48, 2.23) for focal depth of 30 mm. There was, on average, a 35.5%, 41.5%, and 30.7% reduction in PD, RE, and RV’s CNR when the inclusion was centered at 37 compared to 30 mm. Complex inertia correction was not applied to the RV. Acoustic pressure was not adjusted for the higher depth. Future works will evaluate the performance of the portable VisR in viscoelastic phantoms and biological tissues. The study is the first step towards implementing VisR on a portable ultrasound system for point-of-care clinical applications.

Zitieren

APA

Hassan, M. W., Cacko, D., Klimonda, Z., & Hossain, M. M. (2025). Performance evaluation of portable viscoelastic response ultrasound imaging system. The Journal of the Acoustical Society of America, 158(4_Supplement), A429-A429. https://doi.org/10.1121/10.0041395

Vancouver

Hassan MW, Cacko D, Klimonda Z, Hossain MM. Performance evaluation of portable viscoelastic response ultrasound imaging system. The Journal of the Acoustical Society of America. 2025;158(4_Supplement):A429-A429. doi:10.1121/10.0041395

BibTeX
@article{Hassan2025,
  author = {Hassan, Md Walid and Cacko, Damian and Klimonda, Ziemowit and Hossain, Md Murad},
  title = {Performance evaluation of portable viscoelastic response ultrasound imaging system},
  journal = {The Journal of the Acoustical Society of America},
  year = {2025},
  volume = {158},
  number = {4_Supplement},
  pages = {A429--A429},
  doi = {10.1121/10.0041395}
}