Multiwavelength laser diode based portable photoacoustic and ultrasound imaging system for point of care applications
Journal of Biophotonics · 2024
DOI: 10.1002/jbio.202400058 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biophotonics, 2024. Verfasst von Mahaan Mitra und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania, USA. Hauptthemen laut MEDLINE: Photoacoustic Techniques, Ultrasonography, Phantoms, Imaging, Point-of-Care Systems. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIBIB NIH HHS, FIC NIH HHS, NIH HHS.
Abstract (Originalsprache)
Vascular diseases are a leading cause of death and disability worldwide. Despite having precursor conditions like peripheral arterial disease (PAD), they are often only diagnosed after the onset of stroke or heart attack. Low‐cost, portable, noninvasive, point‐of‐care (POC), label‐free assessment of deep vascular function benefits PAD diagnosis, especially in resource poor settings of the world. Doppler ultrasound‐based blood flow measurements can diagnose PAD, albeit with limited sensitivity and specificity. To overcome this, here, we propose the first‐of‐its‐kind dual‐modality photoacoustic‐and‐ultrasound (PAUS) imaging system that integrates a multiwavelength pulsed laser diode (PLD) with a compact ultrasound data acquisition unit. The mesoscopic imaging depth of the portable PLD‐PAUS system was validated using tissue phantoms, and its multispectral photoacoustic imaging capabilities were validated using an atherosclerosis‐mimicking phantom. Furthermore, we demonstrated high‐contrast volumetric in vivo photoacoustic imaging of rodent abdominal vasculature and quantified vessel reactivity due to hypercapnia stimulation. The multiparametric functional and molecular imaging capabilities of the PLD‐PAUS system holds promise for POC applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania, USA.
- Divison of Vascular Surgery, Department of Surgery, The Pennsylvania State University, College of Medicine, Hershey, Pennsylvania, USA.
- Center for Neural Engineering, The Pennsylvania State University, University Park, Pennsylvania, USA.
- Penn State Cancer Institute, The Pennsylvania State University, College of Medicine, Hershey, Pennsylvania, USA.
- Graduate Program in Acoustics, The Pennsylvania State University, University Park, Pennsylvania, USA.
ORCID-Profile: Mahaan Mitra
Förderung
- NIBIB NIH HHS
- FIC NIH HHS
- NIH HHS
- National Institutes of Health
- Fogarty International Center
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Mitra, M., Haworth, A., Gaddale, P., Badran, F., Lagno, N., Pameijer, C., Aziz, F., & Kothapalli, S. R. (2024). Multiwavelength laser diode based portable photoacoustic and ultrasound imaging system for point of care applications. Journal of Biophotonics. https://doi.org/10.1002/jbio.202400058
Vancouver
Mitra M, Haworth A, Gaddale P, Badran F, Lagno N, Pameijer C, et al. Multiwavelength laser diode based portable photoacoustic and ultrasound imaging system for point of care applications. Journal of Biophotonics. 2024. doi:10.1002/jbio.202400058
BibTeX
@article{Mitra2024,
author = {Mitra, Mahaan and Haworth, Abigail and Gaddale, Prameth and Badran, Faisal and Lagno, Nuzhath and Pameijer, Colette and Aziz, Faisal and Kothapalli, Sri-Rajasekhar},
title = {Multiwavelength laser diode based portable photoacoustic and ultrasound imaging system for point of care applications},
journal = {Journal of Biophotonics},
year = {2024},
doi = {10.1002/jbio.202400058}
}
EUVIMED