The effects of extended-wear hearing aids on the localization accuracy of listeners with normal audiometric thresholds

Nathaniel J Spencer, LaGuinn P Sherlock, Nina Pryor, Nandini Iyer, Hilary L Gallagher, Douglas S Brungart

The Journal of the Acoustical Society of America · 2024

DOI: 10.1121/10.0026596 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, 2024. Verfasst von Nathaniel J Spencer und 5 weiteren Autor:innen. Beteiligte Einrichtung: Air Force Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433, USA. Hauptthemen laut MEDLINE: Hearing Aids, Sound Localization, Auditory Threshold. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Medical Research and Materiel Command.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Extended-wear hearing aids (EWHAs) are small broadband analog amplification devices placed deeply enough in the ear canal to preserve most of the cues in the head-related transfer function. However, little is known about how EWHAs affect localization accuracy for normal hearing threshold (NHT) listeners. In this study, eight NHT participants were fitted with EWHAs and localized broadband sounds of different durations (250 ms and 4 s) and stimulus intensities (40, 50, 60, 70, and 80 dBA) in a spherical speaker array. When the EWHAs were in the active mode, localization accuracy was only slightly degraded relative to open-ear performance. However, when the EWHAs were turned off, localization performance was substantially degraded even at the highest stimulus intensities. An electro-acoustical evaluation of the EWHAs showed minimal effects of dynamic range compression on the signals and good preservation of the signal pattern for vertical polar sound localization. Between-study comparisons suggest that EWHA active mode localization accuracy is favorable compared to conventional active earplugs, and EWHA passive mode localization accuracy is comparable to conventional passive earplugs. These results suggest that the deep-insertion analog design of the EWHA is generally better at preserving localization accuracy of NHT listeners than conventional earplug devices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hearing AidsSound LocalizationAuditory ThresholdHumansAdultMaleFemaleYoung AdultAcoustic StimulationCuesEquipment Design

Autor:innen und Institutionen

  • Air Force Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433, USA.
  • Walter Reed National Military Medical Center, Bethesda, Maryland 20889, USA.

Förderung

  • Medical Research and Materiel Command

Zitieren

APA

Spencer, N. J., Sherlock, L. P., Pryor, N., Iyer, N., Gallagher, H. L., & Brungart, D. S. (2024). The effects of extended-wear hearing aids on the localization accuracy of listeners with normal audiometric thresholds. The Journal of the Acoustical Society of America. https://doi.org/10.1121/10.0026596

Vancouver

Spencer NJ, Sherlock LP, Pryor N, Iyer N, Gallagher HL, Brungart DS. The effects of extended-wear hearing aids on the localization accuracy of listeners with normal audiometric thresholds. The Journal of the Acoustical Society of America. 2024. doi:10.1121/10.0026596

BibTeX
@article{Spencer2024,
  author = {Spencer, Nathaniel J and Sherlock, LaGuinn P and Pryor, Nina and Iyer, Nandini and Gallagher, Hilary L and Brungart, Douglas S},
  title = {The effects of extended-wear hearing aids on the localization accuracy of listeners with normal audiometric thresholds},
  journal = {The Journal of the Acoustical Society of America},
  year = {2024},
  doi = {10.1121/10.0026596}
}
Kostenlos starten →