Bimodal Cochlear Implants: Measurement of the Localization Performance as a Function of Device Latency Difference
Trends in Hearing · 2025
DOI: 10.1177/23312165251396658 ↗Kurz gefasst
Fachartikel in der Zeitschrift Trends in Hearing, 2025. Verfasst von Rebecca C Felsheim und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department für Medizinische Physik und Akustik, Carl von Ossietzky Universität Oldenburg, Oldenburg, Germany. Hauptthemen laut MEDLINE: Cochlear Implants, Sound Localization, Cochlear Implantation, Persons with Hearing Disabilities. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Bimodal cochlear implant users show poor localization performance. One reason for this is a difference in the processing latency between the hearing aid and the cochlear implant side. It has been shown that reducing this latency difference acutely improves the localization performance of bimodal cochlear implant users. However, due to the frequency dependency of both the device latencies and the acoustic hearing ear, current frequency-independent latency adjustments cannot fully compensate for the differences, leaving open which latency adjustment is best. We therefore measured the localization performance of 11 bimodal cochlear implant users for multiple cochlear implant latencies. We confirmed previous studies that adjusting the interaural latency improves localization in most of our subjects. However, the latency that leads to the best localization performance for most subjects was not necessarily at the latency estimated to compensate for the interaural difference at intermediate frequencies (1 kHz). Nine of 11 subjects localized best with a cochlear implant latency that was slightly shorter than the estimated latency compensation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department für Medizinische Physik und Akustik, Carl von Ossietzky Universität Oldenburg, Oldenburg, Germany.
- Cluster of Excellence "Hearing4All", Oldenburg, Germany.
- Department of Otolaryngology, Head and Neck Surgery, Carl von Ossietzky Universität Oldenburg, Oldenburg, Germany.
- Research Center Neurosensory Science, University of Oldenburg, Carl von Ossietzky Universität Oldenburg, Oldenburg, Germany.
ORCID-Profile: Rebecca C Felsheim, Mathias Dietz
Zitieren
APA
Felsheim, R. C., Hochmuth, S., Kleinow, A., Radeloff, A., & Dietz, M. (2025). Bimodal Cochlear Implants: Measurement of the Localization Performance as a Function of Device Latency Difference. Trends in Hearing. https://doi.org/10.1177/23312165251396658
Vancouver
Felsheim RC, Hochmuth S, Kleinow A, Radeloff A, Dietz M. Bimodal Cochlear Implants: Measurement of the Localization Performance as a Function of Device Latency Difference. Trends in Hearing. 2025. doi:10.1177/23312165251396658
BibTeX
@article{Felsheim2025,
author = {Felsheim, Rebecca C and Hochmuth, Sabine and Kleinow, Alina and Radeloff, Andreas and Dietz, Mathias},
title = {Bimodal Cochlear Implants: Measurement of the Localization Performance as a Function of Device Latency Difference},
journal = {Trends in Hearing},
year = {2025},
doi = {10.1177/23312165251396658}
}
EUVIMED