Flexural pulse wave velocity in blood vessels
The Journal of the Acoustical Society of America · 2024
DOI: 10.1121/10.0025855 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, 2024. Verfasst von Sibylle Gregoire und 4 weiteren Autor:innen. Beteiligte Einrichtung: LabTAU, INSERM, Université Lyon 1, Lyon 69003, France. Hauptthemen laut MEDLINE: Pulse Wave Analysis, Vascular Stiffness, Phantoms, Imaging, Models, Cardiovascular. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: France Life Imaging.
Abstract (Originalsprache)
Arteriosclerosis is a major risk factor for cardiovascular disease and results in arterial vessel stiffening. Velocity estimation of the pulse wave sent by the heart and propagating into the arteries is a widely accepted biomarker. This symmetrical pulse wave propagates at a speed which is related to the Young's modulus through the Moens Korteweg (MK) equation. Recently, an antisymmetric flexural wave has been observed in vivo. Unlike the symmetrical wave, it is highly dispersive. This property offers promising applications for monitoring arterial stiffness and early detection of atheromatous plaque. However, as far as it is known, no equivalent of the MK equation exists for flexural pulse waves. To bridge this gap, a beam based theory was developed, and approximate analytical solutions were reached. An experiment in soft polymer artery phantoms was built to observe the dispersion of flexural waves. A good agreement was found between the analytical expression derived from beam theory and experiments. Moreover, numerical simulations validated wave speed dependence on the elastic and geometric parameters at low frequencies. Clinical applications, such as arterial age estimation and arterial pressure measurement, are foreseen.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- LabTAU, INSERM, Université Lyon 1, Lyon 69003, France.
- ImPhys, Technische Universiteit Delft, Delft 2628 CJ, The Netherlands.
- Institute of Geophysics, ETH Zurich, Zürich 8092, Switzerland.
- Institut Langevin, CNRS, Université PSL, Paris 75005, France.
ORCID-Profile: Sibylle Gregoire, Gabrielle Laloy-Borgna, Johannes Aichele, Fabrice Lemoult, Stefan Catheline
Förderung
- France Life Imaging
Zitieren
APA
Gregoire, S., Laloy-Borgna, G., Aichele, J., Lemoult, F., & Catheline, S. (2024). Flexural pulse wave velocity in blood vessels. The Journal of the Acoustical Society of America. https://doi.org/10.1121/10.0025855
Vancouver
Gregoire S, Laloy-Borgna G, Aichele J, Lemoult F, Catheline S. Flexural pulse wave velocity in blood vessels. The Journal of the Acoustical Society of America. 2024. doi:10.1121/10.0025855
BibTeX
@article{Gregoire2024,
author = {Gregoire, Sibylle and Laloy-Borgna, Gabrielle and Aichele, Johannes and Lemoult, Fabrice and Catheline, Stefan},
title = {Flexural pulse wave velocity in blood vessels},
journal = {The Journal of the Acoustical Society of America},
year = {2024},
doi = {10.1121/10.0025855}
}