EUVIMEDEUVIMED entdecken
Crossref

Contrast-enhanced ultrasound imaging using capacitive micromachined ultrasonic transducers

Sigrid Husebø Øygard iD, Martin Lind Ommen, Borislav Gueorguiev Tomov, Søren Elmin Diederichsen, Erik Vilain Thomsen, Matthias Bo Stuart, Niels Bent Larsen, Jørgen Arendt Jensen

The Journal of the Acoustical Society of America · 2023

DOI: 10.1121/10.0017533 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, 2023. Verfasst von Sigrid Husebø Øygard und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Technology, Technical University of Denmark, DK-2800 Lyngby, Denmark. Hauptthemen laut MEDLINE: Ultrasonics, Transducers. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Højteknologifonden, Innovationsfonden.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Capacitive micromachined ultrasonic transducers (CMUTs) have a nonlinear relationship between the applied voltage and the emitted signal, which is detrimental to conventional contrast enhanced ultrasound (CEUS) techniques. Instead, a three-pulse amplitude modulation (AM) sequence has been proposed, which is not adversely affected by the nonlinearly emitted harmonics. In this paper, this is shown theoretically, and the performance of the sequence is verified using a 4.8 MHz linear capacitive micromachined ultrasonic transducer (CMUT) array, and a comparable lead zirconate titanate (PZT) array, across 6–60 V applied alternating current (AC) voltage. CEUS images of the contrast agent SonoVue flowing through a 3D printed hydrogel phantom showed an average enhancement in contrast-to-tissue ratio (CTR) between B-mode and CEUS images of 49.9 and 37.4 dB for the PZT array and CMUT, respectively. Furthermore, hydrophone recordings of the emitted signals showed that the nonlinear emissions from the CMUT did not significantly degrade the cancellation in the compounded AM signal, leaving an average of 2% of the emitted power between 26 and 60 V of AC. Thus, it is demonstrated that CMUTs are capable of CEUS imaging independent of the applied excitation voltage when using a three-pulse AM sequence.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

UltrasonicsTransducersUltrasonographyPhantoms, ImagingContrast MediaEquipment Design

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Health Technology, Technical University of Denmark, DK-2800 Lyngby, Denmark.

ORCID-Profile: Sigrid Husebø Øygard

Förderung

  • Højteknologifonden
  • Innovationsfonden

Zitieren

APA

Øygard, S. H., Ommen, M. L., Tomov, B. G., Diederichsen, S. E., Thomsen, E. V., Stuart, M. B., Larsen, N. B., & Jensen, J. A. (2023). Contrast-enhanced ultrasound imaging using capacitive micromachined ultrasonic transducers. The Journal of the Acoustical Society of America. https://doi.org/10.1121/10.0017533

Vancouver

Øygard SH, Ommen ML, Tomov BG, Diederichsen SE, Thomsen EV, Stuart MB, et al. Contrast-enhanced ultrasound imaging using capacitive micromachined ultrasonic transducers. The Journal of the Acoustical Society of America. 2023. doi:10.1121/10.0017533

BibTeX
@article{ygard2023,
  author = {Øygard, Sigrid Husebø and Ommen, Martin Lind and Tomov, Borislav Gueorguiev and Diederichsen, Søren Elmin and Thomsen, Erik Vilain and Stuart, Matthias Bo and Larsen, Niels Bent and Jensen, Jørgen Arendt},
  title = {Contrast-enhanced ultrasound imaging using capacitive micromachined ultrasonic transducers},
  journal = {The Journal of the Acoustical Society of America},
  year = {2023},
  doi = {10.1121/10.0017533}
}
Kostenlos starten →