Spectral correction of light emitting diodes enables accurate hydration ratio calculation using narrowband diffuse reflectance spectroscopy
Journal of Biomedical Optics · 2023
DOI: 10.1117/1.jbo.28.7.075005 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomedical Optics, 2023. Verfasst von Jesse H Lam und 4 weiteren Autor:innen. Beteiligte Einrichtung: Dankook University, Beckman Laser Institute Korea, School of Medicine, Cheonan, Republic of Korea. Hauptthemen laut MEDLINE: Refractometry, Water. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
SignificanceLight emitting diodes (LEDs) are commonly utilized for tissue spectroscopy due to their small size, low cost, and simplicity. However, LEDs are often approximated as single-wavelength devices despite having relatively broad spectral bandwidths. When paired with photodiodes, the wavelength information of detected light cannot be resolved. This can result in errors during chromophore concentration calculations. These errors are particularly apparent when analyzing water and fat in the 900 to 1000 nm window where the spectral bandwidth of LEDs can encompass much of the analysis region, resulting in intense crosstalk.AimWe utilize and present a spectral correction (SC) algorithm to correct for the spectral bandwidth of LEDs. We show the efficacy using a narrowband technique of spectrally broad and overlapping LEDs.ApproachNarrowband diffuse reflectance spectroscopy (nb-DRS), a technique capable of quantifying the hydration ratio (RH2O) of turbid media, was utilized. nb-DRS typically requires a broadband light source and spectrometer. We reduce the hardware to just five LEDs and a photodiode detector, relying on SC to compensate for spectral crosstalk. The effectiveness of our SC approach was tested in simulations as well as in an emulsion phantom and limited selection of human tissue.ResultsIn simulations, we show that calculated RH2O errors increased with the spectral bandwidth of LEDs but could be corrected using SC. Likewise, in emulsions, we found an average error of 8.7% (maximum error 14%) if SC was not used. By contrast, applying SC reduced the average error to 2.2% (maximum error of 6.4%). We show that despite utilizing multiple, spectrally broad, and overlapping LEDs, SC was still able to restore the performance of our narrowband method, making it comparable to a much larger full broadband system.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Dankook University, Beckman Laser Institute Korea, School of Medicine, Cheonan, Republic of Korea.
- Dankook University, Department of Biomedical Engineering, Cheonan, Republic of Korea.
- Dankook University, MEDiThings Co. Ltd., Industry-Academia Cooperation, Cheonan, Republic of Korea.
- University of California, Irvine, Beckman Laser Institute, Department of Biomedical Engineering, Irvine, California, United States.
ORCID-Profile: Sehwan Kim
Zitieren
APA
Lam, J. H., Kim, J., Tu, K. J., Kim, D., & Kim, S. (2023). Spectral correction of light emitting diodes enables accurate hydration ratio calculation using narrowband diffuse reflectance spectroscopy. Journal of Biomedical Optics. https://doi.org/10.1117/1.jbo.28.7.075005
Vancouver
Lam JH, Kim J, Tu KJ, Kim D, Kim S. Spectral correction of light emitting diodes enables accurate hydration ratio calculation using narrowband diffuse reflectance spectroscopy. Journal of Biomedical Optics. 2023. doi:10.1117/1.jbo.28.7.075005
BibTeX
@article{Lam2023,
author = {Lam, Jesse H and Kim, Jeonghun and Tu, Kelsey J and Kim, Dongbin and Kim, Sehwan},
title = {Spectral correction of light emitting diodes enables accurate hydration ratio calculation using narrowband diffuse reflectance spectroscopy},
journal = {Journal of Biomedical Optics},
year = {2023},
doi = {10.1117/1.jbo.28.7.075005}
}
EUVIMED