EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

Megan E. Eckart, Gregory V. Brown, Meng P. Chiao, Renata S. Cumbee, Ryuichi Fujimoto, Natalie Hell, Akio Hoshino, Yoshitaka Ishisaki, Richard L. Kelley, Steven J. Kenyon, Caroline A. Kilbourne, Shunji Kitamoto und 20 weitere

Journal of Astronomical Telescopes, Instruments, and Systems · 29.12.2025 · 11 (04) · 1-27

DOI: 10.1117/1.jatis.11.4.042018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Astronomical Telescopes, Instruments, and Systems, erschienen am 29.12.2025. Verfasst von Megan E. Eckart und 31 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for Promotion of Science (JSPS) KAKENHI, NASA.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ±2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Förderung

  • Japan Society for Promotion of Science (JSPS) KAKENHI
  • NASA

Zitieren

APA

Eckart, M. E., Brown, G. V., Chiao, M. P., Cumbee, R. S., Fujimoto, R., Hell, N., Hoshino, A., Ishisaki, Y., Kelley, R. L., Kenyon, S. J., Kilbourne, C. A., Kitamoto, S., Leutenegger, M. A., Lockard, T., Loewenstein, M., Magee, E. W., Miller, E. D., Mizumoto, M., Porter, F. S., …, & Yaqoob, T. (2025). Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison. Journal of Astronomical Telescopes, Instruments, and Systems, 11(04), 1-27. https://doi.org/10.1117/1.jatis.11.4.042018

Vancouver

Eckart ME, Brown GV, Chiao MP, Cumbee RS, Fujimoto R, Hell N, et al. Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison. Journal of Astronomical Telescopes, Instruments, and Systems. 2025;11(04):1-27. doi:10.1117/1.jatis.11.4.042018

BibTeX
@article{Eckart2025,
  author = {Eckart, Megan E. and Brown, Gregory V. and Chiao, Meng P. and Cumbee, Renata S. and Fujimoto, Ryuichi and Hell, Natalie and Hoshino, Akio and Ishisaki, Yoshitaka and Kelley, Richard L. and Kenyon, Steven J. and Kilbourne, Caroline A. and Kitamoto, Shunji and Leutenegger, Maurice A. and Lockard, Tom and Loewenstein, Michael and Magee, Edward W. and Miller, Eric D. and Mizumoto, Misaki and Porter, F. Scott and Sato, Kosuke and Sawada, Makoto and Shah, Chintan and Shipman, Russell F. and Sneiderman, Gary A. and Takei, Yoh and Tsujimoto, Masahiro and Vries, Cor P. de and Watanabe, Tomomi and Witthoeft, Michael and Wolfs, Rob and Yamada, Shinya and Yaqoob, Tahir},
  title = {Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison},
  journal = {Journal of Astronomical Telescopes, Instruments, and Systems},
  year = {2025},
  volume = {11},
  number = {04},
  pages = {1--27},
  doi = {10.1117/1.jatis.11.4.042018}
}