Fachartikel in der Zeitschrift Journal of Vacuum Science & Technology B, online erschienen am 02.06.2026. Verfasst von Ravindra Patil und 2 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Kyung Hee University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-resolution x-ray imaging under low-voltage conditions is essential for nondestructive evaluation of lithium-ion batteries, where microscale internal defects critically affect safety and long-term performance. However, many previously reported electron emission sources exhibit limitations in beam confinement, particularly under low-voltage or high-current operating conditions, which can restrict imaging resolution and practical applicability. To address these challenges, a newly optimized single-island C-beam x-ray source based on a carbon nanotube (CNT) cold-cathode field emitter is proposed for low-voltage, high-resolution battery inspection. The electron source was optimized through improved electrode geometry and electrostatic focusing, resulting in enhanced beam convergence and reduced focal spot size. Electrical characterization demonstrated reliable operation, delivering a maximum emission current of 1.15 mA in a diode mode and a stable anode current of 0.42 mA in a triode mode. These improvements enabled the formation of a tightly confined focal spot of approximately 32 μm at an anode voltage of 65 kV. Imaging performance was quantitatively validated using line-pair phantoms, confirming a practical spatial resolution of 38.5 μm with contrast-to-noise ratio values ranging from 1.6 to 5.47 under low-dose conditions. The optimized system further achieved high-throughput capability, supporting inspection rates of 300–500 cylindrical cells/min, surpassing conventional low-voltage commercial x-ray systems. The proposed CNT-based C-beam source demonstrates a compact, energy-efficient, and scalable solution for rapid, low-dose, and high-fidelity nondestructive inspection of advanced energy storage devices.

Förderung

  • Kyung Hee University

Zitieren

APA

Patil, R., Karande, A., & Park, K. C. (2026). Fabrication of carbon nanotube-based cold electron source for x-ray battery inspection. Journal of Vacuum Science & Technology B, 44(4). https://doi.org/10.1116/6.0005505

Vancouver

Patil R, Karande A, Park KC. Fabrication of carbon nanotube-based cold electron source for x-ray battery inspection. Journal of Vacuum Science & Technology B. 2026;44(4). doi:10.1116/6.0005505

BibTeX
@article{Patil2026,
  author = {Patil, Ravindra and Karande, Aniket and Park, Kyu Chang},
  title = {Fabrication of carbon nanotube-based cold electron source for x-ray battery inspection},
  journal = {Journal of Vacuum Science & Technology B},
  year = {2026},
  volume = {44},
  number = {4},
  doi = {10.1116/6.0005505}
}
Kostenlos starten →