Contrast-enhanced ultrasound versus conventional ultrasound in guided liver puncture biopsy: a systematic review and meta-analysis
Medical Ultrasonography · 2024
DOI: 10.11152/mu-4374 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Medical Ultrasonography, 2024. Verfasst von Lidan Yang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology Meishan People's Hospital, Meishan, Sichuan. Hauptthemen laut MEDLINE: Contrast Media, Image-Guided Biopsy, Liver, Ultrasonography, Interventional. Die Arbeit wurde bisher 2-mal zitiert (Crossref).
Abstract (Originalsprache)
Aim
To evaluate the contrast-enhanced ultrasound (CEUS) versus conventional ultrasound (US) in guided liver puncture biopsy through a systematic review and meta-analysis.Material and methods: Comparative studies on CEUS and US in liver puncture biopsy were systematically searched from PubMed, Embase, Cochrane library, Chinese Biomedical Literature Database. Two researchers independently screened and extracted data, and RevMan 5.3 software was used for data analysis.
Results
The area under the curve (AUC) for CEUS and US in diagnosing liver biopsy was 0.98 (95%CI 0.99-0.97) and 0.95 (95%CI 0.97-0.93), respectively. CEUS demonstrated significantly higher single puncture success rate (38.0% vs 36.4%) [OR=2.67; 95% CI 1.38-5 .17; p=0 .003] and pathological diagnosis rate (95.6% vs 90.5%) [OR =4.35; 95%CI 2.25 -8.39; p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Gastroenterology Meishan People's Hospital, Meishan, Sichuan.
- Department of Hepatobiliary and Pancreatic Surgery, Meishan People's Hospital, Meishan, Sichuan.
- Department of Gastroenterology Meishan People's Hospital, Meishan, Sichuan. ywqmssrmyy@outlook.com.
Zitieren
APA
Yang, L., Zhang, T., Wang, L., Du, J., Zhang, H., & Yi, W. (2024). Contrast-enhanced ultrasound versus conventional ultrasound in guided liver puncture biopsy: a systematic review and meta-analysis. Medical Ultrasonography. https://doi.org/10.11152/mu-4374
Vancouver
Yang L, Zhang T, Wang L, Du J, Zhang H, Yi W. Contrast-enhanced ultrasound versus conventional ultrasound in guided liver puncture biopsy: a systematic review and meta-analysis. Medical Ultrasonography. 2024. doi:10.11152/mu-4374
BibTeX
@article{Yang2024,
author = {Yang, Lidan and Zhang, Ting and Wang, Lei and Du, Juan and Zhang, Hao and Yi, Wenquan},
title = {Contrast-enhanced ultrasound versus conventional ultrasound in guided liver puncture biopsy: a systematic review and meta-analysis},
journal = {Medical Ultrasonography},
year = {2024},
doi = {10.11152/mu-4374}
}
EUVIMED