Multiscale Architecture Governs Stability in Suction-Actuated Variable Stiffness Catheters
Journal of Biomechanical Engineering · 01.07.2026 · 148 (7)
DOI: 10.1115/1.4071866 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, online erschienen am 03.06.2026. Verfasst von DeVaughn G Rucker und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, The Center Cardiovascular Innovation in Surgery and Engineering (CVISE), Washington University, St. Louis MO 63130; Department…. Hauptthemen laut MEDLINE: Catheters, Mechanical Phenomena. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS.
Abstract (Originalsprache)
Endovascular procedures require devices with widely varying mechanical properties: flexibility for navigating tortuous vessels, and rigidity for stable therapeutic delivery. Suction-actuated variable stiffness sheaths attempt to address this challenge by incorporating axial wire string arrays that couple mechanically under suction to increase flexural rigidity. However, prototype devices achieve stiffening ratios well below theoretical predictions, suggesting that string array positioning and interlayer mechanics require investigation. We therefore investigated whether interweaving expanded polytetrafluoroethylene (PTFE) tape within the string array can enhance flexural rigidity modulation and improve bending uniformity along the catheter length. Prototypes with varying PTFE wrap configurations were fabricated and evaluated using three complementary approaches. First, flexural testing revealed that flexural rigidity in the actuated and unactuated states was largely unaffected by wrapping for small deformations. Second, curvature stability testing revealed that deformation through acute simulated vascular bends was higher than expected due to two failure mechanisms: slip, in which string arrays migrate after overcoming wrap-imposed friction, and buckling, in which arrays become locally pinned and deflect against the outer lumen. Finally, a mathematical model characterized stability limits as functions of the wrapping architecture and device mechanical properties, revealing criteria for which device performance improved. Results suggest design principles for intracatheter wrapping that can narrow the gap between theoretical and achieved flexural rigidity ratios, potentially contributing to the development of endovascular devices capable of single-sheath navigation and intervention.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Surgery, The Center Cardiovascular Innovation in Surgery and Engineering (CVISE), Washington University, St. Louis MO 63130; Department of Biomedical Engineering, Washington University School of Medicine,…
- Department of Surgery, The Center Cardiovascular Innovation in Surgery and Engineering (CVISE), Washington University, St. Louis MO 63130; Department of Mechanical Engineering & Materials Science, Washington University…
- Division of Neurotechnology, Department of Neurological Surgery, Washington University School of Medicine, St. Louis, MO 63110; NSF Science and Technology Center for Engineering Mechanobiology, St. Louis 63130, MO.
- Washington University in St. Louis.
- NSF Science and Technology Center for Engineering Mechanobiology, Department of Mechanical Engineering & Materials Science, Washington University, St. Louis, MO 63130.
- Department of Surgery, The Center Cardiovascular Innovation in Surgery and Engineering (CVISE), Washington University, St. Louis, MO 63130; Department of Mechanical Engineering & Materials Science, Washington University…
ORCID-Profile: Charles B Suskin, Guy M Genin
Förderung
- NHLBI NIH HHS
Zitieren
APA
Rucker, D. G., Lee, S., Qiu, M. Y., Huang, Y., Becerra-García, J., Jin, H., Suskin, C. B., Connor, M., Pyeatte, S., Osbun, J. W., Zayed, M. A., & Genin, G. M. (2026). Multiscale Architecture Governs Stability in Suction-Actuated Variable Stiffness Catheters. Journal of Biomechanical Engineering, 148(7). https://doi.org/10.1115/1.4071866
Vancouver
Rucker DG, Lee S, Qiu MY, Huang Y, Becerra-García J, Jin H, et al. Multiscale Architecture Governs Stability in Suction-Actuated Variable Stiffness Catheters. Journal of Biomechanical Engineering. 2026;148(7). doi:10.1115/1.4071866
BibTeX
@article{Rucker2026,
author = {Rucker, DeVaughn G and Lee, Sheridan and Qiu, Michael Y and Huang, Yuxuan and Becerra-García, Juan and Jin, Hanxun and Suskin, Charles B and Connor, Michelle and Pyeatte, Sophia and Osbun, Joshua W and Zayed, Mohamed A and Genin, Guy M},
title = {Multiscale Architecture Governs Stability in Suction-Actuated Variable Stiffness Catheters},
journal = {Journal of Biomechanical Engineering},
year = {2026},
volume = {148},
number = {7},
doi = {10.1115/1.4071866}
}
EUVIMED