EUVIMEDEUVIMED entdecken
Open Access

Dynamic Rigidity Control for Supportive Sheaths in Endovascular Procedures

Michael Y Qiu, Vinay Chandrasekaran, Chase M Hartquist, Halle R Lowe, Charles B Suskin iD, Sheridan Lee, Juan Becerra-Garcia, Jin Vivian Lee iD, DeVaughn B Rucker, Michelle R Connor, Sophia R Pyeatte, Mohamed S Zaghloul und 5 weitere

Journal of Biomechanical Engineering · 01.07.2025 · 147 (7)

DOI: 10.1115/1.4068225 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, online erschienen am 15.05.2025. Verfasst von Michael Y Qiu und 16 weiteren Autor:innen. Beteiligte Einrichtung: Division of Neurotechnology, Department of Neurological Surgery, Washington University School of Medicine, St. Louis, MO 63110;NSF Science and Techno…. Hauptthemen laut MEDLINE: Endovascular Procedures, Mechanical Phenomena. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, National Science Foundation, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Endovascular procedures require sheaths with contradictory mechanical properties: flexibility for navigation through tortuous vessels, yet rigidity for device delivery. Current approaches rely on multiple device exchanges, increasing procedural time, and complication risks. Here we present a novel endovascular sheath design scheme with dynamically controllable flexural rigidity along its entire length. The device incorporates axially aligned metal string arrays between inner and outer lumens, enabling transition between flexible and rigid states through suction actuation. Three-point bend testing demonstrated that actuation increases flexural rigidity from the range associated with diagnostic catheters to that associated with support sheaths. In simulated contralateral access procedures, the device reduced access time to 1/3 of the time required when using conventional approaches. in vivo porcine studies validated the sheath's ability to navigate tortuous anatomy in its flexible state and successfully support advancement of increasingly rigid therapeutic devices when actuated. Technology enables single-sheath delivery of treatment, potentially reducing procedural complexity, decreasing complication rates, and improving patient outcomes across various endovascular interventions. This design represents a promising approach to combining catheter and sheath design that benefits both peripheral and neurovascular procedures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Endovascular ProceduresMechanical PhenomenaAnimalsSwineEquipment DesignCatheters

Autor:innen und Institutionen

  • Division of Neurotechnology, Department of Neurological Surgery, Washington University School of Medicine, St. Louis, MO 63110;NSF Science and Technology Center for Engineering Mechanobiology, Department of Biomedical E…
  • Division of Neurotechnology, Department of Neurological Surgery, Washington University School of Medicine, St. Louis, MO 63110;NSF Science and Technology Center for Engineering Mechanobiology, Department of Computer Sci…
  • Division of Neurotechnology, Department of Neurological Surgery, Washington University School of Medicine, St. Louis, MO 63110;NSF Science and Technology Center for Engineering Mechanobiology, Department of Mechanical E…
  • Division of Neurotechnology, Department of Neurological Surgery, Washington University School of Medicine, St. Louis, MO 63110;Department of Biomedical Engineering, Washington University, St. Louis, MO 63130.
  • CVISE, The Center Cardiovascular Innovation in Surgery and Engineering, Department of Surgery, Washington University School of Medicine, St. Louis, MO 63110;NSF Science and Technology Center for Engineering Mechanobiolo…
  • CVISE, The Center Cardiovascular Innovation in Surgery and Engineering, Department of Surgery, Washington University School of Medicine, St. Louis, MO 63110.

ORCID-Profile: Charles B Suskin, Jin Vivian Lee

Förderung

  • NIH HHS
  • National Science Foundation
  • National Institutes of Health

Zitieren

APA

Qiu, M. Y., Chandrasekaran, V., Hartquist, C. M., Lowe, H. R., Suskin, C. B., Lee, S., Becerra-Garcia, J., Lee, J. V., Rucker, D. B., Connor, M. R., Pyeatte, S. R., Zaghloul, M. S., Elizondo Benedetto, S., Leuthardt, E. C., Zayed, M. A., Osbun, J. W., & Genin, G. M. (2025). Dynamic Rigidity Control for Supportive Sheaths in Endovascular Procedures. Journal of Biomechanical Engineering, 147(7). https://doi.org/10.1115/1.4068225

Vancouver

Qiu MY, Chandrasekaran V, Hartquist CM, Lowe HR, Suskin CB, Lee S, et al. Dynamic Rigidity Control for Supportive Sheaths in Endovascular Procedures. Journal of Biomechanical Engineering. 2025;147(7). doi:10.1115/1.4068225

BibTeX
@article{Qiu2025,
  author = {Qiu, Michael Y and Chandrasekaran, Vinay and Hartquist, Chase M and Lowe, Halle R and Suskin, Charles B and Lee, Sheridan and Becerra-Garcia, Juan and Lee, Jin Vivian and Rucker, DeVaughn B and Connor, Michelle R and Pyeatte, Sophia R and Zaghloul, Mohamed S and Elizondo Benedetto, Santiago and Leuthardt, Eric C and Zayed, Mohamed A and Osbun, Joshua W and Genin, Guy M},
  title = {Dynamic Rigidity Control for Supportive Sheaths in Endovascular Procedures},
  journal = {Journal of Biomechanical Engineering},
  year = {2025},
  volume = {147},
  number = {7},
  doi = {10.1115/1.4068225}
}
Kostenlos starten →