EUVIMEDEUVIMED entdecken
Open Access

Benchtop Pulse Wave Velocity Measurement From Spatial Wavelength Rather Than Pulse Arrival Time: Feasibility Studies

Jason A Franzman iD, Joshua Do, Manali Rajendra Kulkarni, John-Paul Heinzen, Hadi Wiputra, Victor Barocas

Journal of Biomechanical Engineering · 2026

DOI: 10.1115/1.4071257 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2026. Verfasst von Jason A Franzman und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering & Materials Science, University of Minnesota, Minneapolis, MN 55414-1226. Hauptthemen laut MEDLINE: Pulse Wave Analysis. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Arterial stiffness is a significant predictor of cardiovascular disease, commonly assessed using pulse wave velocity (PWV). Traditional PWV measurement methods, such as time-of-flight, become unreliable in highly reflective systems due to the presence of standing waves and measurement noise, complicating accurate determination of wave arrival times. To address these limitations, we developed and validated a spatial wavelength-based PWV measurement approach. Our objective was to evaluate the capability of this method in nonbiological systems and compare its performance directly to standard methods. Experimental measurements were conducted using latex tubes in a benchtop pulsatile flow system across multiple frequencies (20-47 Hz). High-speed video analysis tracked spatial diameter changes, allowing identification of the spatial wavelength. Computational fluid-structure interaction (FSI) simulations, replicating experimental conditions, provided validation. Measuring PWV via spatial wavelength showed consistent accuracy when compared to traditional methods (phase-slope, peak-slope, and pressure arrival time), remaining within 12% error relative to theoretical predictions derived from the Moens-Korteweg equation. Spatial wavelength-based calculation has practical limitations, including reduced reliability near resonant frequencies and the requirement for at least one full wavelength within the length of measured region, constraining clinical usability. This method can be used in laboratory conditions at higher frequencies, potentially allowing quantification of how vascular implants and prosthetics could alter arterial wall dynamics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulse Wave AnalysisFeasibility StudiesTime FactorsPulsatile FlowComputer SimulationReproducibility of Results

Autor:innen und Institutionen

  • Department of Chemical Engineering & Materials Science, University of Minnesota, Minneapolis, MN 55414-1226.
  • Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN 55455.
  • Department of Aerospace Engineering and Mechanics, University of Minnesota, Minneapolis, MN 55455.
  • University of Minnesota.

ORCID-Profile: Jason A Franzman

Förderung

  • NHLBI NIH HHS

Zitieren

APA

Franzman, J. A., Do, J., Kulkarni, M. R., Heinzen, J. P., Wiputra, H., & Barocas, V. (2026). Benchtop Pulse Wave Velocity Measurement From Spatial Wavelength Rather Than Pulse Arrival Time: Feasibility Studies. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4071257

Vancouver

Franzman JA, Do J, Kulkarni MR, Heinzen JP, Wiputra H, Barocas V. Benchtop Pulse Wave Velocity Measurement From Spatial Wavelength Rather Than Pulse Arrival Time: Feasibility Studies. Journal of Biomechanical Engineering. 2026. doi:10.1115/1.4071257

BibTeX
@article{Franzman2026,
  author = {Franzman, Jason A and Do, Joshua and Kulkarni, Manali Rajendra and Heinzen, John-Paul and Wiputra, Hadi and Barocas, Victor},
  title = {Benchtop Pulse Wave Velocity Measurement From Spatial Wavelength Rather Than Pulse Arrival Time: Feasibility Studies},
  journal = {Journal of Biomechanical Engineering},
  year = {2026},
  doi = {10.1115/1.4071257}
}
Kostenlos starten →