EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Feasibility, Repeatability, and Correlation to Lung Function of Phase‐Resolved Functional Lung ( PREFUL ) MRI ‐derived Pulmonary Artery Pulse Wave Velocity Measurements

Marius M Wernz iD, Andreas Voskrebenzev, Robin A Müller, Maximilian Zubke, Filip Klimeš iD, Julian Glandorf iD, Christoph Czerner, Frank Wacker, Karen M Olsson, Marius M Hoeper, Jens M Hohlfeld, Jens Vogel-Claussen iD

Journal of Magnetic Resonance Imaging · 2024

DOI: 10.1002/jmri.29337 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2024. Verfasst von Marius M Wernz und 11 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany. Hauptthemen laut MEDLINE: Pulmonary Artery, Feasibility Studies, Pulse Wave Analysis, Pulmonary Disease, Chronic Obstructive. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: German Center for Lung Research (DZL), Deutsches Zentrum für Lungenforschung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pulse wave velocity (PWV) in the pulmonary arteries (PA) is a marker of vascular stiffening. Currently, only phase‐contrast (PC) MRI‐based options exist to measure PA‐PWV.

Purpose

To test feasibility, repeatability, and correlation to clinical data of Phase‐Resolved Functional Lung (PREFUL) MRI‐based calculation of PA‐PWV. Study Type Retrospective. Subjects 79 (26 female) healthy subjects (age range 19–78), 58 (24 female) patients with chronic obstructive pulmonary disease (COPD, age range 40–77), 60 (33 female) patients with suspected pulmonary hypertension (PH, age range 28–85). Sequence 2D spoiled gradient echo, 1.5T. Assessment PA‐PWV was measured from PREFUL‐derived cardiac cycles based on the determination of temporal and spatial distance between lung vasculature voxels using a simplified (sPWV) method and a more comprehensive (cPWV) method including more elaborate distance calculation. For 135 individuals, PC MRI‐based PWV (PWV‐QA) was measured. Statistical Tests Intraclass‐correlation‐coefficient (ICC) and coefficient of variation (CoV) were used to test repeatability. Nonparametric tests were used to compare cohorts. Correlation of sPWV/cPWV, PWV‐QA, forced expiratory volume in 1 sec (FEV 1 ) %predicted, residual volume (RV) %predicted, age, and right heart catheterization (RHC) data were tested. Significance level α = 0.05 was used. Results sPWV and cPWV showed no significant differences between repeated measurements ( P ‐range 0.10–0.92). CoV was generally lower than 15%. COPD and PH patients had significantly higher sPWV and cPWV than healthy subjects. Significant correlation was found between sPWV or cPWV and FEV 1 %pred. ( R = −0.36 and R = −0.44), but not with RHC ( P ‐range −0.11 − 0.91) or age ( P ‐range 0.23–0.89). Correlation to RV%pred. was significant for cPWV ( R = 0.42) but not for sPWV ( R = 0.34, P = 0.055). For all cohorts, sPWV and cPWV were significantly correlated with PWV‐QA ( R = −0.41 and R = 0.48). Data Conclusion PREFUL‐derived PWV is feasible and repeatable. PWV is increased in COPD and PH patients and correlates to airway obstruction and hyperinflation. Level of Evidence 3 Technical Efficacy Stage 2

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary ArteryFeasibility StudiesPulse Wave AnalysisPulmonary Disease, Chronic ObstructiveLungMagnetic Resonance ImagingHumansFemaleMiddle AgedMaleAgedAdultReproducibility of ResultsRetrospective StudiesAged, 80 and overYoung AdultHypertension, PulmonaryRespiratory Function Tests

Stichwörter der Autor:innen

COPDlungpulmonary circulationpulmonary hypertensionpulse wave velocity

Autor:innen und Institutionen

  • Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.
  • Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), German Center for Lung Research (DZL), Hannover, Germany.
  • Department of Nuclear Medicine, Hannover Medical School, Hannover, Germany.
  • Department of Respiratory Medicine and Infectious Diseases, Hannover Medical School, Hannover, Germany.
  • Fraunhofer Institute for Toxicology and Experimental Medicine, Hannover, Germany.

ORCID-Profile: Marius M Wernz, Filip Klimeš, Julian Glandorf, Jens Vogel-Claussen

Förderung

  • German Center for Lung Research (DZL)
  • Deutsches Zentrum für Lungenforschung

Zitieren

APA

Wernz, M. M., Voskrebenzev, A., Müller, R. A., Zubke, M., Klimeš, F., Glandorf, J., Czerner, C., Wacker, F., Olsson, K. M., Hoeper, M. M., Hohlfeld, J. M., & Vogel-Claussen, J. (2024). Feasibility, Repeatability, and Correlation to Lung Function of Phase‐Resolved Functional Lung ( PREFUL ) MRI ‐derived Pulmonary Artery Pulse Wave Velocity Measurements. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29337

Vancouver

Wernz MM, Voskrebenzev A, Müller RA, Zubke M, Klimeš F, Glandorf J, et al. Feasibility, Repeatability, and Correlation to Lung Function of Phase‐Resolved Functional Lung ( PREFUL ) MRI ‐derived Pulmonary Artery Pulse Wave Velocity Measurements. Journal of Magnetic Resonance Imaging. 2024. doi:10.1002/jmri.29337

BibTeX
@article{Wernz2024,
  author = {Wernz, Marius M and Voskrebenzev, Andreas and Müller, Robin A and Zubke, Maximilian and Klimeš, Filip and Glandorf, Julian and Czerner, Christoph and Wacker, Frank and Olsson, Karen M and Hoeper, Marius M and Hohlfeld, Jens M and Vogel-Claussen, Jens},
  title = {Feasibility, Repeatability, and Correlation to Lung Function of Phase‐Resolved Functional Lung ( PREFUL ) MRI ‐derived Pulmonary Artery Pulse Wave Velocity Measurements},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1002/jmri.29337}
}
Kostenlos starten →