An In Situ Examination of Running Specific Prostheses Stiffness Properties

Paige M Agnew iD, Hunter J Bennett, Stacie I Ringleb

Journal of Biomechanical Engineering · 2026

DOI: 10.1115/1.4070500 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2026. Verfasst von Paige M Agnew und 2 weiteren Autor:innen. Beteiligte Einrichtung: Ellmer College of Health Sciences, Old Dominion University, 1007 Student Recreation Center, 4700 Powhatan Avenue, Norfolk, VA 23529. Hauptthemen laut MEDLINE: Running, Artificial Limbs, Mechanical Phenomena, Materials Testing. Die Arbeit nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Since the development of running specific prostheses (RSPs) in the 1980s, individuals with lower limb loss have been able to engage in more modes of physical activity including running competitively and recreationally. Researchers have been led to investigate different mechanical properties like stiffness and hysteresis using machine testing. However, machine testing is limited by loading and deformation rates that are well below those recorded during running. The purpose of this investigation is to examine the mechanical properties of RSPs in situ. Three-dimensional motion capture and force platforms were used to record deformation and external loading while two participants ran at their 1-mile pace using their prescribed prosthetic device. Linear and nonlinear prosthetic stiffness and hysteresis were calculated for each trial across loading and restoration phases using the vector magnitudes of three-dimensional force and deformation measured via markers affixed to the prosthesis. Linear stiffness during the loading phase was relatively similar across participants (∼26 kN/m), despite differences in prosthesis type, body mass, and running speeds. However, linear stiffness was reduced by 5–10% during the restoration phase. Overall, both prostheses force–deformation relationships were nonlinear, exhibiting variable stiffness throughout each phase, a crossover point (“pinched hysteresis curve”), and smooth transitions between loading and restoration phases. Machine tested stiffness values from the literature were approximately 5 kN/m lower compared to in situ stiffness values. These findings illustrate the importance of understanding the in situ properties for RSPs, user applications, and clinical recommendations for prostheses prescription.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RunningArtificial LimbsMechanical PhenomenaMaterials TestingHumansMaleAdultBiomechanical PhenomenaFemale

Autor:innen und Institutionen

  • Ellmer College of Health Sciences, Old Dominion University, 1007 Student Recreation Center, 4700 Powhatan Avenue, Norfolk, VA 23529.
  • Old Dominion University.
  • Batten College of Engineering, Old Dominion University, 238 Kaufman Hall, Norfolk, VA 23529.

ORCID-Profile: Paige M Agnew

Zitieren

APA

Agnew, P. M., Bennett, H. J., & Ringleb, S. I. (2026). An In Situ Examination of Running Specific Prostheses Stiffness Properties. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4070500

Vancouver

Agnew PM, Bennett HJ, Ringleb SI. An In Situ Examination of Running Specific Prostheses Stiffness Properties. Journal of Biomechanical Engineering. 2026. doi:10.1115/1.4070500