Thermal Performance Characterization of Dry Gas Seals in a Supercritical Carbon Dioxide Compressor

Rahul A. Bidkar, Uttara Kumar, Xiaohua Zhang, Nora Molino, Joshua Neveu, John Klaerner, Jeremy Johnson, J. Jeffery Moore

Journal of Turbomachinery · 01.12.2025 · 147 (12)

DOI: 10.1115/1.4068988 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Turbomachinery, online erschienen am 17.07.2025. Verfasst von Rahul A. Bidkar und 7 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: Office of Fossil Energy.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Commercially available dry gas seals (DGSs) are the seal-of-choice for shaft-end sealing locations in compressors used in the oil and gas industry and supercritical carbon dioxide (sCO2) power cycles. The DGS’s reliability is tied to how well the 2–7 µm gas/supercritical fluid film is sustained under varying pressure, thermal, and speed conditions. Recent sCO2 turbomachinery development efforts have experienced a couple of catastrophic DGS failures at the compressor shaft-end locations. A suspected root cause of these DGS failures is thermal deformations caused by the excessive windage heating expected with the supercritical CO2 working fluid when the compressor operates at high pressures and high rotational speeds. In this work, the thermal behavior of the DGS operating in a typical sCO2 compressor is investigated. Specifically, test data are presented for a specially instrumented, commercially available DGS operating in the GE-SwRI sCO2 compressor operating under various mission points. The test data show higher than expected temperatures (about 190 °C) in the cavities surrounding the DGS, which provides useful insights to turbomachinery designers for designing seal cavities. Furthermore, the measured temperatures are compared with the predictions of a steady-state thermal model of the GE-SwRI sCO2 compressor. The thermal model uses a 1D flow advection network with cavity swirl solvers, windage, and heat transfer coefficients for sCO2 flow exchanging heat with the surrounding structure. The predictions of the thermal model match reasonably well with the measured temperature data, thereby providing validation to the novel sCO2 thermal modeling assumptions.

Förderung

  • Office of Fossil Energy

Zitieren

APA

Bidkar, R. A., Kumar, U., Zhang, X., Molino, N., Neveu, J., Klaerner, J., Johnson, J., & Moore, J. J. (2025). Thermal Performance Characterization of Dry Gas Seals in a Supercritical Carbon Dioxide Compressor. Journal of Turbomachinery, 147(12). https://doi.org/10.1115/1.4068988

Vancouver

Bidkar RA, Kumar U, Zhang X, Molino N, Neveu J, Klaerner J, et al. Thermal Performance Characterization of Dry Gas Seals in a Supercritical Carbon Dioxide Compressor. Journal of Turbomachinery. 2025;147(12). doi:10.1115/1.4068988

BibTeX
@article{Bidkar2025,
  author = {Bidkar, Rahul A. and Kumar, Uttara and Zhang, Xiaohua and Molino, Nora and Neveu, Joshua and Klaerner, John and Johnson, Jeremy and Moore, J. Jeffery},
  title = {Thermal Performance Characterization of Dry Gas Seals in a Supercritical Carbon Dioxide Compressor},
  journal = {Journal of Turbomachinery},
  year = {2025},
  volume = {147},
  number = {12},
  doi = {10.1115/1.4068988}
}
Kostenlos starten →