Analysis and Implications of Compliance on Joint Biomechanics Measurements in Superposition Testing
Journal of Biomechanical Engineering · 2025
DOI: 10.1115/1.4068634 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2025. Verfasst von Callan M Gillespie und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering and Lerner Research Institute, Cleveland Clinic Foundation, 2111 E 96th Street, Cleveland, OH 44106; Department …. Hauptthemen laut MEDLINE: Mechanical Phenomena, Joints, Materials Testing, Mechanical Tests. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
To quantify the contributions of specific ligaments to overall joint movement, the principle of superposition has been used for nearly 30 years. This principle relies on using a robotic test system to move a biological joint to the same position before and after transecting a specific ligament. The resulting difference in joint forces is assumed to be the transected ligament's tension. However, the robotic test system's ability to accurately return the joint to the commanded pose is dependent on the compliance of the system's various components, which is often neglected. Accordingly, there were three objectives in this paper: (1) Explain the influence of system compliance on positioning error in superposition testing with a mathematical model, (2) Quantify the compliance of components within the robotic test system, and (3) Provide a framework to evaluate uncertainty in published superposition based in situ force measurements and demonstrate their implications on published anterior cruciate ligament (ACL) forces. A system stiffness model (SSM) was derived to explain that compliance of test system components will cause the superposition method to underestimate ligament tension and stiffness. Based on typical test system component and joint stiffness ranges measured in this study, it was determined that with decreasing robot and/or bone stiffness, or increasing joint stiffness values, ligament load error could increase to values greater than 50%. Results indicate that experimentalists should (1) maximize test system component stiffness relative to joint stiffness and/or (2) compensate for compliance induced deflection of the test system components.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Biomedical Engineering and Lerner Research Institute, Cleveland Clinic Foundation, 2111 E 96th Street, Cleveland, OH 44106; Department of Applied Biomedical Engineering, Cleveland State University, 2111 E…
- Cleveland Clinic.
- Department of Biomedical Engineering and Lerner Research Institute, Cleveland Clinic Foundation, 2111 E 96th Street, Cleveland, OH 44106.
Zitieren
APA
Gillespie, C. M., Haas, N. J., Nagle, T. F., & Colbrunn, R. W. (2025). Analysis and Implications of Compliance on Joint Biomechanics Measurements in Superposition Testing. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4068634
Vancouver
Gillespie CM, Haas NJ, Nagle TF, Colbrunn RW. Analysis and Implications of Compliance on Joint Biomechanics Measurements in Superposition Testing. Journal of Biomechanical Engineering. 2025. doi:10.1115/1.4068634
BibTeX
@article{Gillespie2025,
author = {Gillespie, Callan M and Haas, Nicholas J and Nagle, Tara F and Colbrunn, Robb W},
title = {Analysis and Implications of Compliance on Joint Biomechanics Measurements in Superposition Testing},
journal = {Journal of Biomechanical Engineering},
year = {2025},
doi = {10.1115/1.4068634}
}
EUVIMED