Four-Dimensional Visualization of Topological Fixed Points in Pulsatile Cardiovascular Flows
Journal of Biomechanical Engineering · 2025
DOI: 10.1115/1.4068078 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2025. Verfasst von Thangam Natarajan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332. Hauptthemen laut MEDLINE: Pulsatile Flow, Models, Cardiovascular, Imaging, Three-Dimensional. Die Arbeit nennt 57 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
Topological features of time-dependent, three-dimensional (3D) vector flow fields, such as wall shear stress (WSS) fixed points, are considered surrogates of pathological blood flow dynamics in cardiovascular diseases. Fixed-point visualizations are typically constrained to two-dimensional (2D) spaces, yet they aim to display complex spatiotemporal (four-dimensional (4D)) dynamics. There is a need for visualization strategies to reduce occlusion and reliance on animations to allow the detection of holistic flow patterns. Using intracranial aneurysms as a use case, we present the fixed-point carousel, a novel approach to visually depicting the “4D” nature of WSS fixed points via (1) topographic mapping of the 3D aneurysm sac to overcome occlusion while preserving fixed-point distances and sac morphological features; and (2) arranging these into a carousel model to present with temporal dimension holistically. Examples are presented for image-based computational fluid dynamic (CFD) models of intracranial aneurysms, illuminating the intricate and distinct fixed-point trajectories and interactions, a necessary step toward understanding the volumetric flow manifolds that drive them for this and other cardiovascular—and potentially nonbiomedical—fluid dynamics applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332.
- Georgia Institute of Technology.
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada; Faculty of Design, OCAD University, Toronto, ON M5S 3G8, Canada.
- University of Toronto.
- Faculty of Design, OCAD University, Toronto, ON M5S 3G8, Canada.
- Ontario College of Art and Design.
ORCID-Profile: Peter W Coppin, David A Steinman
Förderung
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Natarajan, T., Husain, Z., Coppin, P. W., & Steinman, D. A. (2025). Four-Dimensional Visualization of Topological Fixed Points in Pulsatile Cardiovascular Flows. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4068078
Vancouver
Natarajan T, Husain Z, Coppin PW, Steinman DA. Four-Dimensional Visualization of Topological Fixed Points in Pulsatile Cardiovascular Flows. Journal of Biomechanical Engineering. 2025. doi:10.1115/1.4068078
BibTeX
@article{Natarajan2025,
author = {Natarajan, Thangam and Husain, Zainab and Coppin, Peter W and Steinman, David A},
title = {Four-Dimensional Visualization of Topological Fixed Points in Pulsatile Cardiovascular Flows},
journal = {Journal of Biomechanical Engineering},
year = {2025},
doi = {10.1115/1.4068078}
}
EUVIMED