EUVIMEDEUVIMED entdecken
Crossref

Simultaneous Evaluation of Tibiofemoral and Patellofemoral Mechanics in Total Knee Arthroplasty: A Combined Experimental and Computational Approach

Yashar A Behnam, Ahilan Anantha Krishnan, Hayden Wilson, Chadd W Clary

Journal of Biomechanical Engineering · 2024

DOI: 10.1115/1.4063950 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2024. Verfasst von Yashar A Behnam und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Materials Engineering, University of Denver, 2155 East Wesley Avenue, Denver, CO 80210. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Patellofemoral Joint, Knee Prosthesis. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 56 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Contemporary total knee arthroplasty (TKA) has not fully restored natural patellofemoral (P-F) mechanics across the patient population. Previous experimental simulations have been limited in their ability to create dynamic, unconstrained, muscle-driven P-F articulation while simultaneously controlling tibiofemoral (T-F) contact mechanics. The purpose of this study was to develop a novel experimental simulation and validate a corresponding finite element model to evaluate T-F and P-F mechanics. A commercially available wear simulator was retrofitted with custom fixturing to evaluate whole-knee TKA mechanics with varying patella heights during a simulated deep knee bend. A corresponding dynamic finite element model was developed to validate kinematic and kinetic predictions against experimental measurements. Patella alta reduced P-F reaction forces in early and midflexion, corresponding with an increase in T-F forces that indicated an increase in extensor mechanism efficiency. Due to reduced wrapping of the extensor mechanism in deeper flexion for the alta condition, peak P-F forces in flexion increased from 101% to 135% of the applied quadriceps load for the baja and alta conditions, respectively. Strong agreement was observed between the experiment and model predictions with root-mean-square errors (RMSE) for P-F kinematics ranging from 0.8 deg to 3.3 deg and 0.7 mm to 1.4 mm. RMSE for P-F forces ranged from 7.4 N to 53.6 N. By simultaneously controlling dynamic, physiological loading of the T-F and P-F joint, this novel experimental simulation and validated model will be a valuable tool for investigation of future TKA designs and surgical techniques.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneePatellofemoral JointKnee ProsthesisHumansKnee JointKneePatellaBiomechanical PhenomenaRange of Motion, Articular

Autor:innen und Institutionen

  • Department of Mechanical and Materials Engineering, University of Denver, 2155 East Wesley Avenue, Denver, CO 80210.

Zitieren

APA

Behnam, Y. A., Anantha Krishnan, A., Wilson, H., & Clary, C. W. (2024). Simultaneous Evaluation of Tibiofemoral and Patellofemoral Mechanics in Total Knee Arthroplasty: A Combined Experimental and Computational Approach. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4063950

Vancouver

Behnam YA, Anantha Krishnan A, Wilson H, Clary CW. Simultaneous Evaluation of Tibiofemoral and Patellofemoral Mechanics in Total Knee Arthroplasty: A Combined Experimental and Computational Approach. Journal of Biomechanical Engineering. 2024. doi:10.1115/1.4063950

BibTeX
@article{Behnam2024,
  author = {Behnam, Yashar A and Anantha Krishnan, Ahilan and Wilson, Hayden and Clary, Chadd W},
  title = {Simultaneous Evaluation of Tibiofemoral and Patellofemoral Mechanics in Total Knee Arthroplasty: A Combined Experimental and Computational Approach},
  journal = {Journal of Biomechanical Engineering},
  year = {2024},
  doi = {10.1115/1.4063950}
}
Kostenlos starten →