Systematic Assessment of Prosthesis Stiffness on User Biomechanics Using the Lower Leg Trajectory Error Framework and Its Implication for the Design and Evaluation of Ankle-Foot Prostheses
Journal of Biomechanical Engineering · 2023
DOI: 10.1115/1.4056137 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2023. Verfasst von Victor Prost und 4 weiteren Autor:innen. Beteiligte Einrichtung: GEAR Laboratory, Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139. Hauptthemen laut MEDLINE: Leg, Artificial Limbs. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 67 Literaturangaben. Gefördert von: Office of the Assistant Secretary for Health.
Abstract (Originalsprache)
Advances in understanding the effects the mechanical characteristics of prosthetic feet on user biomechanics have enabled passive prostheses to improve the walking pattern of people with lower limb amputation. However, there is no consensus on the design methodology and criteria required to maximize specific user outcomes and fully restore their mobility. The Lower Leg Trajectory Error (LLTE) framework is a novel design methodology based on the replication of lower leg dynamics. The LLTE value evaluates how closely a prosthetic foot replicates a target walking pattern. Designing a prosthesis that minimizes the LLTE value, optimizes its mechanical function to enable users to best replicate the target lower leg trajectory. Here, we conducted a systematic sensitivity investigation of LLTE-optimized prostheses. Five people with unilateral transtibial amputation walked overground at self-selected speeds using five prototype energy storage and return feet with varying LLTE values. The prototypes' LLTE values were varied by changing the stiffness of the participant's LLTE-optimized design by 60%, 80%, 120%, and 167%. Users most closely replicated the target able-bodied walking pattern with the LLTE-optimized stiffness, experimentally demonstrating that the predicted optimum was a true optimum. Additionally, the predicted LLTE values were correlated to the user's ability to replicate the target walking pattern, user preferences, and clinical outcomes including roll-over geometries, trunk sway, prosthetic energy return, and peak push-off power. This study further validates the use of the LLTE framework as a predictive and quantitative tool for designing and evaluating prosthetic feet.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- GEAR Laboratory, Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139.
- Department of Integrated Health Sciences, University of Nevada, Las Vegas, NV 89154.
- Department of Physical Medicine and Rehabilitation, Northwestern University, Jesse Brown VA Medical Center, Chicago, IL 60611; Department of Biomedical Engineering, Northwestern University, Jesse Brown VA Medical Center…
Förderung
- Office of the Assistant Secretary for Health
Zitieren
APA
Prost, V., Johnson, W. B., Kent, J. A., Major, M. J., & Winter, A. G. (2023). Systematic Assessment of Prosthesis Stiffness on User Biomechanics Using the Lower Leg Trajectory Error Framework and Its Implication for the Design and Evaluation of Ankle-Foot Prostheses. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4056137
Vancouver
Prost V, Johnson WB, Kent JA, Major MJ, Winter AG. Systematic Assessment of Prosthesis Stiffness on User Biomechanics Using the Lower Leg Trajectory Error Framework and Its Implication for the Design and Evaluation of Ankle-Foot Prostheses. Journal of Biomechanical Engineering. 2023. doi:10.1115/1.4056137
BibTeX
@article{Prost2023,
author = {Prost, Victor and Johnson, W Brett and Kent, Jenny A and Major, Matthew J and Winter, Amos G},
title = {Systematic Assessment of Prosthesis Stiffness on User Biomechanics Using the Lower Leg Trajectory Error Framework and Its Implication for the Design and Evaluation of Ankle-Foot Prostheses},
journal = {Journal of Biomechanical Engineering},
year = {2023},
doi = {10.1115/1.4056137}
}
EUVIMED