EUVIMEDEUVIMED entdecken
Open Access

Biomechanical Engineering Analysis of Pulmonary Valve Leaflet Hemodynamics and Kinematics in the Ross Procedure

Yuanjia Zhu, Robert J Wilkerson, Pearly K Pandya, Danielle M Mullis, Catherine A Wu, Sarah Madira, Mateo Marin-Cuartas, Matthew H Park, Annabel M Imbrie-Moore, Y Joseph Woo

Journal of Biomechanical Engineering · 2023

DOI: 10.1115/1.4055033 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2023. Verfasst von Yuanjia Zhu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic Surgery, Stanford University, Stanford, CA 94304; Department of Bioengineering, Stanford University, Stanford, CA 94304. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Pulmonary Valve. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, National Science Foundation, National Heart, Lung, and Blood Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Ross procedure using the inclusion technique with anticommissural plication (ACP) is associated with excellent valve hemodynamics and favorable leaflet kinematics. The objective was to evaluate individual pulmonary cusp's biomechanics and fluttering by including coronary flow in the Ross procedure using an ex vivo three-dimensional-printed heart simulator. Ten porcine and five human pulmonary autografts were harvested from a meat abattoir and heart transplant patients. Five porcine autografts without reinforcement served as controls. The other autografts were prepared using the inclusion technique with and without ACP (ACP and NACP). Hemodynamic and high-speed videography data were measured using the ex vivo heart simulator. Although porcine autografts showed similar leaflet rapid opening and closing mean velocities, human ACP compared to NACP autografts demonstrated lower leaflet rapid opening mean velocity in the right (p = 0.02) and left coronary cusps (p = 0.003). The porcine and human autograft leaflet rapid opening and closing mean velocities were similar in all three cusps. Porcine autografts showed similar leaflet flutter frequencies in the left (p = 0.3) and noncoronary cusps (p = 0.4), but porcine NACP autografts versus controls demonstrated higher leaflet flutter frequency in the right coronary cusp (p = 0.05). The human NACP versus ACP autografts showed higher flutter frequency in the noncoronary cusp (p = 0.02). The leaflet flutter amplitudes were similar in all three cusps in both porcine and human autografts. The ACP compared to NACP autografts in the Ross procedure was associated with more favorable leaflet kinematics. These results may translate to the improved long-term durability of the pulmonary autografts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve ProsthesisPulmonary ValveAnimalsAortic ValveAutograftsBiomechanical PhenomenaHemodynamicsHumansSwineTransplantation, Autologous

Autor:innen und Institutionen

  • Department of Cardiothoracic Surgery, Stanford University, Stanford, CA 94304; Department of Bioengineering, Stanford University, Stanford, CA 94304.
  • Department of Cardiothoracic Surgery, Stanford University, Stanford, CA 94304.
  • Department of Cardiothoracic Surgery, Stanford University, Stanford, CA 94304; Department of Mechanical Engineering, Stanford University, Stanford, CA 94304.
  • Department of Cardiothoracic Surgery, Stanford University, Stanford, CA 94304; University Department of Cardiac Surgery, Leipzig Heart Center, Leipzig 04289, Germany.
  • Falk Cardiovascular Research Center Department of Cardiothoracic Surgery, Stanford University, MD 300 Pasteur Drive, Stanford, CA 94305; Department of Bioengineering, Stanford University, Stanford, CA 94304.

Förderung

  • NHLBI NIH HHS
  • National Science Foundation
  • National Heart, Lung, and Blood Institute
  • National Institutes of Health
  • Thoracic Surgery Foundation for Research and Education

Zitieren

APA

Zhu, Y., Wilkerson, R. J., Pandya, P. K., Mullis, D. M., Wu, C. A., Madira, S., Marin-Cuartas, M., Park, M. H., Imbrie-Moore, A. M., & Woo, Y. J. (2023). Biomechanical Engineering Analysis of Pulmonary Valve Leaflet Hemodynamics and Kinematics in the Ross Procedure. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4055033

Vancouver

Zhu Y, Wilkerson RJ, Pandya PK, Mullis DM, Wu CA, Madira S, et al. Biomechanical Engineering Analysis of Pulmonary Valve Leaflet Hemodynamics and Kinematics in the Ross Procedure. Journal of Biomechanical Engineering. 2023. doi:10.1115/1.4055033

BibTeX
@article{Zhu2023,
  author = {Zhu, Yuanjia and Wilkerson, Robert J and Pandya, Pearly K and Mullis, Danielle M and Wu, Catherine A and Madira, Sarah and Marin-Cuartas, Mateo and Park, Matthew H and Imbrie-Moore, Annabel M and Woo, Y Joseph},
  title = {Biomechanical Engineering Analysis of Pulmonary Valve Leaflet Hemodynamics and Kinematics in the Ross Procedure},
  journal = {Journal of Biomechanical Engineering},
  year = {2023},
  doi = {10.1115/1.4055033}
}
Kostenlos starten →