EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Longer action potential duration in the Purkinje network than in the ventricular myocardium delays retrograde activation of the human His‐Purkinje system

Jason D Bayer iD, Edward J Vigmond, Ruben Coronel, Chantal E Conrath

The Journal of Physiology · 2026-03-31

DOI: 10.1113/jp290657 ↗

At a glance

Journal article in The Journal of Physiology, published online on 2026-03-31. Written by Jason D Bayer and 3 co-authors. Institution: Electrophysiology and Heart Modeling Institute, IHU Liryc, Fondation Bordeaux Université, Pessac, France. 43 references. The full text is freely available (open access, CC BY 4.0). Funded by: French National Research Agency, Fondation Lefoulon Delalande, GENCI - Grand equipement nationalde calcul intensif.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

His‐Purkinje system (HPS) activation during programmed electrical stimulation is delayed in patients susceptible to ventricular arrhythmias. Its mechanism and clinical relevance are unknown. We hypothesized that longer action potential duration (APD) in the HPS than in the ventricular myocardium delays retrograde HPS activation, and is arrhythmogenic for large APD differences. The right ventricular apex of a computational human ventricles model, with short or long HPS APD, was paced with an S1 cycle length of 600 ms for 10 cycles followed by an S2 stimulus. S1S2 coupling intervals (CIs) started at 400 ms and were reduced by 10 ms steps until the loss of stimulus capture. S1 and S2 activation times (ATs) were computed to determine the S 2 H 2 time, which, when prolonged, is analogous to delayed retrograde HPS activation. Simulations were compared retrospectively to patients who underwent the same protocol ( N = 5). In the model, longer APD in the HPS than in the ventricular myocardium delayed HPS activation as S1S2 CI shortened (60–152 ms), which was similar to patients examined for ventricular arrhythmias (40–160 ms). Delayed HPS activation was due to increased AT (from 11–14 to 31–196 ms) and distance (from 0.3–0.4 to 0.6–5.3 cm) between the myocardial pacing site and the excitable HPS. For the largest difference between myocardial and HPS APD (106 ms), reentry was initiated for S1S2 CI between 270–320 ms. In conclusion, longer APD in the HPS than in the myocardium delayed HPS activation during programmed electrical stimulation. The S1S2 CI‐dependent delay was due to slower and longer pathways from the stimulus site to the HPS, which promoted reentrant tachyarrhythmias for the slowest and longest pathways. image Key points This is the first study to identify the location and mechanism of delayed retrograde activation that leads to increased S 2 H 2 and constant S 1 H 2 times at short S1S2 CIs during programmed electrical stimulation, a phenomenon discovered in 1978. At short S1S2 CI during programmed electrical stimulation, longer APD in the HPS than in the myocardium can lead to entry points into the HPS further away from the myocardial S2 stimulus site and promote reentrant arrhythmias. This is new knowledge regarding the retrograde activation of the human conduction system. The mechanism of delayed retrograde activation was determined using a state‐of‐the‐art computer model of the human ventricles coupled to a robust model of the HPS. As a result, this study developed a new and extensive set of HPS parameters that future computational studies can use and build upon to simulate retrograde activation of the human ventricles.

Subjects

Author keywords

conduction systemmodellingpacingprogrammed electrical stimulationretrograde activationsimulationventricular arrhythmias

Authors and institutions

  • Electrophysiology and Heart Modeling Institute, IHU Liryc, Fondation Bordeaux Université, Pessac, France.
  • Le département Sciences de l'ingénierie et du numérique (SIN), Institut de Mathématiques de Bordeaux (IMB) - UMR5251, Université de Bordeaux, Talence, France.
  • Department of Experimental Cardiology, Amsterdam University Medical Center, Amsterdam, The Netherlands.
  • Department of Cardiology, Amsterdam University Medical Center, Amsterdam, The Netherlands.

ORCID profiles: Jason D Bayer

Funding

  • French National Research Agency
  • Fondation Lefoulon Delalande
  • GENCI - Grand equipement nationalde calcul intensif
  • Agence Nationale de la Recherche

Cite

APA

Bayer, J. D., Vigmond, E. J., Coronel, R., & Conrath, C. E. (2026). Longer action potential duration in the Purkinje network than in the ventricular myocardium delays retrograde activation of the human His‐Purkinje system. The Journal of Physiology. https://doi.org/10.1113/jp290657

Vancouver

Bayer JD, Vigmond EJ, Coronel R, Conrath CE. Longer action potential duration in the Purkinje network than in the ventricular myocardium delays retrograde activation of the human His‐Purkinje system. The Journal of Physiology. 2026. doi:10.1113/jp290657

BibTeX
@article{Bayer2026,
  author = {Bayer, Jason D and Vigmond, Edward J and Coronel, Ruben and Conrath, Chantal E},
  title = {Longer action potential duration in the Purkinje network than in the ventricular myocardium delays retrograde activation of the human His‐Purkinje system},
  journal = {The Journal of Physiology},
  year = {2026},
  doi = {10.1113/jp290657}
}
Start for free →