EUVIMEDSkopri EUVIMED
Open access · CC BY 4.0

Neurophysiological sensitivity to envelope and pulse timing interaural time differences in cochlear implanted rats with different hearing experiences

S Fang iD, T Fleiner iD, F Peng, S Buchholz iD, M Zeeshan, N Rosskothen-Kuhl iD, J W Schnupp iD

The Journal of Physiology · 2026-05 · 604 (10) · 3875-3894

DOI: 10.1113/jp290143 ↗

At a glance

Journal article in The Journal of Physiology, published online on 2026-04-22. Written by S Fang and 6 co-authors. Institution: Department of Neuroscience, City University of Hong Kong, Hong Kong SAR, China. Major MEDLINE topics: Cochlear Implants, Inferior Colliculi, Sound Localization, Hearing. 54 references. The full text is freely available (open access, CC BY 4.0). Funded by: Taube Kinder lernen hoeren e. V., Research Commission of the Medical Faculty of the Medical Centre at the University of Freiburg, MED-EL Medical Electronics.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Cochlear implants (CIs) have successfully restored hearing in more than one million patients with severe to profound hearing loss worldwide. Although CIs effectively restore speech perception in quiet environments, sound localization remains challenging for bilateral CI users, particularly their ability to utilize interaural time differences (ITDs). The majority of clinical CI processors use a coding strategy that encodes ITD information only in the envelope of electrical pulse trains rather than their pulse timing, which may contribute to the poorer spatial hearing perception of CI users. We recently demonstrated in a behavioural study on early deafened, bilaterally CI‐implanted rats that pulse timing ITDs completely dominate ITD perception, whereas sensitivity to envelope ITDs is almost negligible in comparison. Building on this, we here investigated the neurophysiological sensitivity of the inferior colliculus (IC) to envelope and pulse timing ITDs at two different pulse rates (900 and 4500 pulses/s) and three different stimulation modulations (5, 20 and 100 Hz) in CI rats with different hearing experiences. Our results indicate that IC neurons exhibit far greater sensitivity to pulse timing ITD than envelope ITD independent of pulse rate, modulation rate or hearing experience. These findings suggest that to improve binaural hearing outcomes in bilateral CI users, clinical stimulation strategies should provide informative pulse timing ITDs. image Key points Current bilateral cochlear implants mostly provide time cues of arriving sound in the envelope of stimulation rather than in the timing of pulses. A behavioural study on cochlear implanted rats has shown that pulse timing dominates binaural hearing. Here we examined the neural sensitivity to independent changes in time cues presented on the envelope or pulse timing, respectively, in rats with bilateral cochlear implants and different hearing experiences. Auditory midbrain neurons were consistently more sensitive to changes in pulse timing rather than envelope, irrespective of stimulus pulse rate, modulation rate or an animal's hearing experience.

Subjects

MeSH terms (MEDLINE)

Cochlear ImplantsInferior ColliculiSound LocalizationHearingAnimalsRatsMaleNeuronsAcoustic Stimulation

Author keywords

binaural hearingcochlear implantselectrophysiologyinferior colliculusinteraural time differences

Authors and institutions

  • Department of Neuroscience, City University of Hong Kong, Hong Kong SAR, China.
  • Gerald Choa Neuroscience Institute, Chinese University of Hong Kong, Sha Tin, Hong Kong SAR, China.
  • Faculty of Biology, University of Freiburg, Freiburg, Germany.
  • Neurobiological Research Laboratory, Section for Experimental and Clinical Otology, Department of Otolaryngology, Medical Center - University of Freiburg, Medical Faculty, University of Freiburg, Freiburg, Germany.
  • Bernstein Center Freiburg and Faculty of Biology, University of Freiburg, Freiburg, Germany.
  • Department of Otolaryngology, Chinese University of Hong Kong, Hong Kong, China.

ORCID profiles: S Fang, T Fleiner, S Buchholz, N Rosskothen-Kuhl, J W Schnupp

Funding

  • Taube Kinder lernen hoeren e. V.
  • Research Commission of the Medical Faculty of the Medical Centre at the University of Freiburg
  • MED-EL Medical Electronics
  • Hong Kong Health and Medical Research Fund
  • Hong Kong General Research Fund

Cite

APA

Fang, S., Fleiner, T., Peng, F., Buchholz, S., Zeeshan, M., Rosskothen-Kuhl, N., & Schnupp, J. W. (2026). Neurophysiological sensitivity to envelope and pulse timing interaural time differences in cochlear implanted rats with different hearing experiences. The Journal of Physiology, 604(10), 3875-3894. https://doi.org/10.1113/jp290143

Vancouver

Fang S, Fleiner T, Peng F, Buchholz S, Zeeshan M, Rosskothen-Kuhl N, et al. Neurophysiological sensitivity to envelope and pulse timing interaural time differences in cochlear implanted rats with different hearing experiences. The Journal of Physiology. 2026;604(10):3875-3894. doi:10.1113/jp290143

BibTeX
@article{Fang2026,
  author = {Fang, S and Fleiner, T and Peng, F and Buchholz, S and Zeeshan, M and Rosskothen-Kuhl, N and Schnupp, J W},
  title = {Neurophysiological sensitivity to envelope and pulse timing interaural time differences in cochlear implanted rats with different hearing experiences},
  journal = {The Journal of Physiology},
  year = {2026},
  volume = {604},
  number = {10},
  pages = {3875--3894},
  doi = {10.1113/jp290143}
}
Start for free →