EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Motor unit discharge rate modulation during isometric contractions to failure is intensity‐ and modality‐dependent

Tamara Valenčič iD, Paul Ansdell iD, Callum G Brownstein, Padraig M Spillane, Aleš Holobar, Jakob Škarabot iD

The Journal of Physiology · 2024-05 · 602 (10) · 2287-2314

DOI: 10.1113/jp286143 ↗

At a glance

Journal article in The Journal of Physiology, published online on 2024-04-15. Written by Tamara Valenčič and 5 co-authors. Institution: School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK. Major MEDLINE topics: Isometric Contraction. Cited 18 times so far (Crossref); 96 references. The full text is freely available (open access, CC BY 4.0). Funded by: Versus Arthritis Foundation Fellowship, UK Office for Veteran's Affairs, Slovenian Research Agency.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

The physiological mechanisms determining the progressive decline in the maximal muscle torque production capacity during isometric contractions to task failure are known to depend on task demands. Task‐specificity of the associated adjustments in motor unit discharge rate (MUDR), however, remains unclear. This study examined MUDR adjustments during different submaximal isometric knee extension tasks to failure. Participants performed a sustained and an intermittent task at 20% and 50% of maximal voluntary torque (MVT), respectively (Experiment 1). High‐density surface EMG signals were recorded from vastus lateralis (VL) and medialis (VM) and decomposed into individual MU discharge timings, with the identified MUs tracked from recruitment to task failure. MUDR was quantified and normalised to intervals of 10% of contraction time (CT). MUDR of both muscles exhibited distinct modulation patterns in each task. During the 20% MVT sustained task, MUDR decreased until ∼50% CT, after which it gradually returned to baseline. Conversely, during the 50% MVT intermittent task, MUDR remained stable until ∼40–50% CT, after which it started to continually increase until task failure. To explore the effect of contraction intensity on the observed patterns, VL and VM MUDR was quantified during sustained contractions at 30% and 50% MVT (Experiment 2). During the 30% MVT sustained task, MUDR remained stable until ∼80–90% CT in both muscles, after which it continually increased until task failure. During the 50% MVT sustained task the increase in MUDR occurred earlier, after ∼70–80% CT. Our results suggest that adjustments in MUDR during submaximal isometric contractions to failure are contraction modality‐ and intensity‐dependent. image Key points During prolonged muscle contractions a constant motor output can be maintained by recruitment of additional motor units and adjustments in their discharge rate. Whilst contraction‐induced decrements in neuromuscular function are known to depend on task demands, task‐specificity of motor unit discharge behaviour adjustments is still unclear. In this study, we tracked and compared discharge activity of several concurrently active motor units in the vastii muscles during different submaximal isometric knee extension tasks to failure, including intermittent vs . sustained contraction modalities performed in the same intensity domain (Experiment 1), and two sustained contractions performed at different intensities (Experiment 2). During each task, motor units modulated their discharge rate in a distinct, biphasic manner, with the modulation pattern depending on contraction intensity and modality. These results provide insight into motoneuronal adjustments during contraction tasks posing different demands on the neuromuscular system.

Subjects

MeSH terms (MEDLINE)

Isometric ContractionHumansMaleAdultFemaleTorqueYoung AdultMuscle, SkeletalMotor NeuronsElectromyographyQuadriceps MuscleRecruitment, Neurophysiological

Author keywords

decompositionmotoneuronneural driveperformance fatigability

Authors and institutions

  • School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK.
  • Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, UK.
  • School of Biomedical, Nutritional and Sport Sciences, Newcastle University, Newcastle upon Tyne, UK.
  • Faculty of Electrical Engineering and Computer Science, University of Maribor, Maribor, Slovenia.

ORCID profiles: Tamara Valenčič, Paul Ansdell, Jakob Škarabot

Funding

  • Versus Arthritis Foundation Fellowship
  • UK Office for Veteran's Affairs
  • Slovenian Research Agency
  • Horizon Europe Research and Innovation Programme
  • Javna Agencija za Raziskovalno Dejavnost RS

Cite

APA

Valenčič, T., Ansdell, P., Brownstein, C. G., Spillane, P. M., Holobar, A., & Škarabot, J. (2024). Motor unit discharge rate modulation during isometric contractions to failure is intensity‐ and modality‐dependent. The Journal of Physiology, 602(10), 2287-2314. https://doi.org/10.1113/jp286143

Vancouver

Valenčič T, Ansdell P, Brownstein CG, Spillane PM, Holobar A, Škarabot J. Motor unit discharge rate modulation during isometric contractions to failure is intensity‐ and modality‐dependent. The Journal of Physiology. 2024;602(10):2287-2314. doi:10.1113/jp286143

BibTeX
@article{Valeni2024,
  author = {Valenčič, Tamara and Ansdell, Paul and Brownstein, Callum G and Spillane, Padraig M and Holobar, Aleš and Škarabot, Jakob},
  title = {Motor unit discharge rate modulation during isometric contractions to failure is intensity‐ and modality‐dependent},
  journal = {The Journal of Physiology},
  year = {2024},
  volume = {602},
  number = {10},
  pages = {2287--2314},
  doi = {10.1113/jp286143}
}
Start for free →